SIKESTON, MO —
OSHA Inspection: TANK TECH INC/BRIDGEPORT CHEMICAL INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TANK TECH INC/BRIDGEPORT CHEMICAL INC in 3975 ST. HWY H, SIKESTON, MO 63801 (NAICS 325211). OSHA activity number 342042892.
Where did this inspection happen?
- Establishment
- TANK TECH INC/BRIDGEPORT CHEMICAL INC
- Site address
- 3975 ST. HWY H
- City
- SIKESTON
- State
- MO
- ZIP
- 63801
- Mailing
- P.O. BOX 17, BLODGETT, MO 63824
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.1200 G02 II
- Issued
- Abate by
- Penalty
- Initial $3232.00 · Current $2262.00 Reduced
General-duty citation text
29 CFR 1910.1200(g)(2)(ii): The chemical manufacturer or importer preparing the safety data sheet did not ensure that it included Section 2, Hazard identification: a. Section II of the safety data sheet (SDS) for Glass Armor 27P Activator did not identify flammability as a hazard and there was no flammability pictogram. (Note: Section V of the SDS indicates a flashpoint of >105 degrees F which may indicate a Class 4 flammable liquid. Section XV of the SDS lists an HMIS classification for fire of 1, which also indicates a Globalized Harmonization classification of a Class 4 flammable liquid. Either a flammability hazard is required to be included in Section II or correction should be made in Section V and XV.) b. Section II of the SDS for Glass Armor 27P Resin did not identify flammability as a hazard and there was no flammability pictogram. (Note: Section V of the SDS indicates a flashpoint of >150 degrees F which may indicate a Class 4 flammable liquid. Section XV of the SDS lists an HMIS classification for fire of 1, which also indicates a Globalized Harmonization classification of a Class 4 flammable liquid. Either a flammability hazard is required to be included in Section II or correction should be made in Section V and XV.) Abatement documentation is required for this violation.
Recent events (2)
- — I (O) $2262.4
- — Z (S) $3232
1910.1200 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(2)(iii): The chemical manufacturer or importer preparing the safety data sheet did not ensure that it included Section 3, exposure limits: a. Section III of the safety data sheet (SDS) for Glass Armor 27P Activator did not include OSHA permissible exposure limits for three components where limits have been established. b. Section III of the SDS for Glass Armor 27P Resin did not did not include OSHA permissible exposure limits for three components where limits have been established. Abatement documentation is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1200 G02 VIII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(2)(viii): The chemical manufacturer or importer preparing the safety data sheet did not ensure that it included Section 8, Exposure controls/personal protection: a. Section VIII of the safety data sheet (SDS) for Glass Armor 27P Activator did not include more specific information on the type of glove material to be used during handling, when that information was available from ingredient SDS information. b. Section III of the SDS for Glass Armor 27P Resin did not include more specific information on the type of glove material to be used during handling, when that information was available from ingredient SDS information. Abatement documentation is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1200 G02 XI
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(2)(xi): The chemical manufacturer or importer preparing the safety data sheet did not ensure that it included Section 11, Toxicological information: Section XI of the safety data sheet (SDS) for Glass Armor 27P Activator was inconsistent in describing hazards to skin, eyes, and the respiratory tract. In section XI, under Acute Toxicity is stated, "may cause severe eye irritation," "may cause skin burns," and under, Effects of Overexposure, "can result in severe skin, eye, and respiratory irritation," but under Irritation is stated, "extreme corrosive." Extreme corrosive is much more of a hazardous condition than severe irritation. Abatement documentation is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.1200 G02 XV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(2)(xv): 29 CFR 1910.1200(g)(2)(xv): The chemical manufacturer or importer preparing the safety data sheet did not ensure that it included Section 15, Regulatory information: a. Section XV of the safety data sheet (SDS) for Glass Armor 27P Activator listed a Canada HMIS classification for health and fire hazards, however, there is no Canada HMIS system. (Note: there is a Canada WHMIS classification and an HMIS classification system developed by the American Coatings Association. The two classifications are not exactly the same.) b. Section III of the SDS for Glass Armor 27P Resin listed a Canada HMIS classification for health and fire hazards, however, there is no Canada HMIS system. (Note: there is a Canada WHMIS classification and an HMIS classification system developed by the American Coatings Association. The two classifications are not exactly the same.) Abatement documentation is required for this violation.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 325211)
WEST ELIZABETH, PA—2026-07-08
SYNTHOMER INC.
JACKSONVILLE, FL—2026-07-08
POLYNT COMPOSITES USA INC.
PROCTOR, WV—2026-07-06
COVESTRO LLC
ENGLEWOOD, CO—2026-07-01
AVIENT CORPORATION (FORMERLY POLYSTRAND)
BURNSVILLE, MN—2026-06-23
111453 - JM ENTERPRISES
More inspections in MO
KANSAS CITY, MO—2026-07-09
NIAGARA BOTTLING
MONETT, MO—2026-07-09
MONETT METALS INC.
PARKVILLE, MO—2026-07-08
SKY-TECH ROOFING, LLC.
SPRINGFIELD, MO—2026-07-07
D & C CONSTRUCTION, LLC.
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342042892.