OAKWOOD, GA —
OSHA Inspection: PRIMEX PLASTICS CORP.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of PRIMEX PLASTICS CORP. in 3435 OLD OAKWOOD ROAD, OAKWOOD, GA 30566 (NAICS 326112). OSHA activity number 342044351.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PRIMEX PLASTICS CORP.
- Site address
- 3435 OLD OAKWOOD ROAD
- City
- OAKWOOD
- State
- GA
- ZIP
- 30566
- Mailing
- 3435 OLD OAKWOOD ROAD, OAKWOOD, GA 30566
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 169
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.95 B01
- Issued
- Mar 22, 2017
- Abate by
- Sep 25, 2017
- Penalty
- Initial $500 · Current $0 Reduced
8110
General-duty citation text
29 CFR 1910.95(b)(1): When employees were subjected to sound exceeding those listed in Table G-16, feasible administrative or engineering controls were not utilized: a) Primex Plastics Corp., Oakwood, GA - An employee operating the grinder on line 12 was exposed to noise at a TWA of 103.9 dBA which exceeded the permissible exposure limit of 90 dBA. Effective engineering controls to decrease noise exposure were not accomplished. The exposure was derived from a personal sample taken over 452 minutes, on or about 2/3/17. b) Primex Plastics Corp., Oakwood, GA - An employee operating the grinders in the grinding room was exposed to noise at a TWA of 107.4 dBA which exceeded the permissible exposure limit of 90 dBA. Effective engineering controls to decrease noise exposure were not accomplished. The exposure was derived from a personal sample taken over 467 minutes, on or about 2/3/17.
Recent events (2)
- — I (O) $0
- — Z (O) $500
More inspections at Primex Plastics Corp.
View Primex Plastics Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 326112)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342044351.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.