EVANS CITY, PA —
OSHA Inspection: MARBURGER FARM DAIRY INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MARBURGER FARM DAIRY INC. in 1506 MARS-EVANS CITY ROAD, EVANS CITY, PA 16033 (NAICS 311511). OSHA activity number 342044468.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARBURGER FARM DAIRY INC.
- Site address
- 1506 MARS-EVANS CITY ROAD
- City
- EVANS CITY
- State
- PA
- ZIP
- 16033
- Mailing
- 1506 MARS-EVANS CITY ROAD, EVANS CITY, PA 16033
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311511
- Employees
- 130
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C04 I
- Issued
- Feb 13, 2017
- Abate by
- Mar 31, 2017
- Penalty
- Initial $8,311 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: (a) Facility, 1506 Mars-Evans City Road, Evans City, PA: On or before January 23, 2017 the employer did not have a procedure for the control of hazardous energy for employees who perform maintenance on the HTST2 equipment. On January 19, 2017 an employee involved in a maintenance task was injured when they were sprayed with pressurized, hot water. There was no specific energy control procedure in place to address the sources of energy for the equipment and what methods could be used to control the energy.
Recent events (2)
- — I (S) $5000
- — Z (S) $8311
1910.147 C06 I
- Issued
- Feb 13, 2017
- Abate by
- Mar 3, 2017
- Penalty
- Initial $4,155 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) Facility, 1506 Mars-Evans City Road, Evans City, PA: On or about January 23, 2017 the employer had not conducted an periodic inspection of the energy control procedure at least annually. The last periodic inspection record was dated June 4, 2015.
Recent events (2)
- — I (S) $3000
- — Z (S) $4155
More inspections at Marburger Farm Dairy INC.
View Marburger Farm Dairy INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311511)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342044468.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.