Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CREEDE REPERTORY THEATRE INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CREEDE REPERTORY THEATRE INC in 124 N MAIN ST, CREEDE, CO 81130 (NAICS 711110). OSHA activity number 342044674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Creede Repertory Theatre INC — free Get an email when a new federal OSHA severe-injury report for Creede Repertory Theatre INC is published. One employer, no account, unsubscribe in one click.
Site address
124 N MAIN ST
City
CREEDE
State
CO
ZIP
81130
Mailing
PO BOX 269, CREEDE, CO 81130
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
711110
Employees
63
Ownership type
A

3 citations on file for this inspection.

1910.28 B05 I

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $8,873 · Current $5,324 Reduced
29 CFR 1910.28(b)(5)(i): The employer did not ensure each employee on a runway or similar walkway was protected from falling 4 feet (1.2 m) or more to a lower level by a guardrail system:    (a) On or about August 24, 2016, and at times prior, Creede Repertory Theater, Inc. did not ensure that each employee on a runway or similar walkway was protected from falling 4 feet or more to a lower level by a guardrail system. In the main theater grid, employees were exposed to fall hazards of up to 21 feet while conducting electrical work on top of three walkways located across the grid. Walkways were not guarded by railings.      Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $5323.8
  • — Z (S) $8873

1910.28 C

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.28(c): When an employee is exposed to falling objects, the employer did not ensure that each employee wore head protection that meets the requirements of 29 CFR part 1910, subpart I.:  (a) On or about August 24, 2016, and at times prior, Creede Repertory Theater, Inc. did not ensure that employees working on the main theater stage were wearing head protection while work overhead was being performed. Employees working on the stage were exposed to falling object hazards in that items such as, but not limited to, light fixtures weighing up to 22 lbs. were installed, repaired, replaced, and/or maintained 21 feet above the stage.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Feb 6, 2017
Abate by
Mar 3, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.28(c)(1): The employer did not erect toeboards, screens, or guardrail systems to prevent objects from falling to a lower level:  (a) On or about August 24, 2016, and at times prior, Creede Repertory Theater, Inc. did not ensure that toeboards, screens or guardrail systems were erected to prevent objects from falling to a lower level.           1. Employees working on the stage were exposed to falling object hazards in that electricians were required to install,  repair, replace, and/or maintain light fixtures and other electrical equipment while working from three walkways 21 feet above the stage. The walkways did not have toeboards, screens, or guardrail systems to prevent items such as, but not limited to, 22 lb. light fixtures, tools, and equipment from falling down to the stage.       2. Employees working on the stage were exposed to falling object hazards in that the guardrail system installed on the perimeter of the grid did not have toeboards or screens installed to prevent items such as, but not limited to, 22 lb. light fixtures, tools, and equipment from falling 21 feet down to the stage.  Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342044674.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.