Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BENITO TORREZ DBA TORREZ CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BENITO TORREZ DBA TORREZ CONSTRUCTION in 34 N. WARRINGTON STREET, DES PLAINES, IL 60016 (NAICS 238130). OSHA activity number 342047339.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benito Torrez DBA Torrez Construction — free Get an email when a new federal OSHA severe-injury report for Benito Torrez DBA Torrez Construction is published. One employer, no account, unsubscribe in one click.
Site address
34 N. WARRINGTON STREET
City
DES PLAINES
State
IL
ZIP
60016
Mailing
119 WALLACE COURT, CHICAGO HEIGHTS, IL 60411
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
2
Ownership type
A

5 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 4 instances 1 exposed
Issued
Mar 9, 2017
Penalty
Initial $3,803 · Current $1,940 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):                a) On or about January 24, 2017, employees were exposed to the hazard of falling approximately 19 feet from the top of a wall to the exterior of the building while performing carpentry work.       b) On or about January 24, 2017, employees were exposed to the hazard of falling approximately 12 feet from second level window/wall openings to the exterior of the building while performing carpentry work.         No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $1940
  • — Z (S) $3803

1926.1052 C01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 9, 2017
Penalty
Initial $3,259 · Current $1,660 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:         a) On or about January 24, 2017, employees were exposed to fall hazards of up to approximately 12 feet where a stairway between the first and second level of the building was not equipped with a stairrail system along its unprotected side or edge.         No abatement certification or documentation required for this violation.
Recent events (2)
  • — I (S) $1660
  • — Z (S) $3259

1926.404 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Mar 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:           a) On or about January 24, 2017, employees were provided with electrical tools and equipment connected by cord and plug to a Yamaha 2600 watt portable generator without the use of ground fault circuit interrupters or an assured equipment grounding conductor program.             In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.416 E01

Other-than-serious 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Mar 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:       a) On or about January 24, 2017, worn and frayed electrical cords were used to supply electricity to tools and equipment at the site.        In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1926.503 B01

Other-than-serious 1 instance 1 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify fall protection training by preparing a written certification record:         a) On or about January 24, 2017, the employer did not prepare written certification records related to employee fall protection training.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342047339.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.