CARROLLTON, GA —
OSHA Inspection: PILGRIM'S PRIDE CORPORATION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of PILGRIM'S PRIDE CORPORATION in 616 KINGSBRIDGE ROAD, CARROLLTON, GA 30117 (NAICS 311615). OSHA activity number 342047826.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PILGRIM'S PRIDE CORPORATION
- Site address
- 616 KINGSBRIDGE ROAD
- City
- CARROLLTON
- State
- GA
- ZIP
- 30117
- Mailing
- 616 KINGSBRIDGE ROAD, CARROLLTON, GA 30117
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311615
- Employees
- 582
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.95 I03
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.95(i)(3): Employees were not given the opportunity to select their hearing protectors from a variety of suitable hearing protectors provided by the employer: a) Throughout the facility- On or about January 23, 2017, and at times prior, employees processing chickens were not offered a variety of hearing protection by the employer. Employees were not offered ear muffs free of charge during the hiring process.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.1026 D01
- Issued
- Jul 14, 2017
- Abate by
- Aug 30, 2017
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): (a) Production areas- On or about January 23, 2017, initial air monitoring was not conducted during stainless steel welding operations to determine the maintenance employees' exposure to hexavalent chromium.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
1910.1200 F10
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(10): The employer did not ensure that workplace labels or other forms of warnings were legible: a) Yard Area, adjacent to the wash bay- On or about January 25, 2017, and at times prior, the employer failed to ensure that workplace labels or other forms of warnings were legible on the liquefied petroleum gas or liquid petroleum gas (LPG or LP gas), storage tank used for heating the Truck Shop.
Recent events (3)
- — J (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Pilgrim'S Pride Corporation
View Pilgrim'S Pride Corporation's full OSHA safety record →
More inspections in this industry (NAICS 311615)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342047826.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.