MANCHESTER, CT —
OSHA Inspection: SATELLITE AEROSPACE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SATELLITE AEROSPACE, INC. in 240 CHAPEL ROAD, MANCHESTER, CT 06045 (NAICS 332116). OSHA activity number 342048022.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SATELLITE AEROSPACE, INC.
- Site address
- 240 CHAPEL ROAD
- City
- MANCHESTER
- State
- CT
- ZIP
- 06045
- Mailing
- P.O. BOX 1077, MANCHESTER, CT 06045
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332116
- Employees
- 19
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.178 A05
- Issued
- Mar 29, 2017
- Abate by
- Jun 27, 2017
- Penalty
- Initial $2,463 · Current $1,724 Reduced
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: A. On or about January 25, 2017, Loading Dock: The Komatsu 25 propane powered industrial truck was used with 72-inch fork extensions. The extensions were not marked on the data plate to show the approximate weight of the truck and extension combination at maximum elevation with a load laterally centered.
Recent events (2)
- — I (S) $1724.1
- — Z (S) $2463
1910.212 A01
- Issued
- Mar 29, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $3,078 · Current $2,155 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: A. On or about January 25, 2017, Shop: 1. The Grob, Inc. vertical metal-cutting band saw, Type 4V-18, S/N 3760, had a 12-inch portion of the blade which was unguarded, exposing employees to amputation hazards. 2. The Westinghouse 1/2 HP 1-inch belt sander had an unguarded in-going nip point at the bottom front pulley, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $2154.6
- — Z (S) $3078
1910.212 A04
- Issued
- Mar 29, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(4): Revolving drum(s), barrel(s), or container(s) were not guarded by enclosure(s) which were interlocked with the drive mechanism so that the barrel(s), drum(s), or container(s) could not revolve unless the enclosure(s) were in place: A. On or about January 25, 2017, Shop: Tumb-L-Matic Tumbler #2 was not guarded to prevent employees from accessing the rotating tumbler during operation. The enclosure door was not interlocked and was kept closed with a removable metal clip.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Mar 29, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $2,463 · Current $1,724 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: A. On or about January 25, 2017, Press Area behind Press #32: A putty-colored four outlet relocatable multiple-outlet extension was plugged in to a black four-outlet multiple-outlet extension, against listing and labeling instructions.
Recent events (2)
- — I (S) $1724.1
- — Z (S) $2463
1910.305 A02 II
- Issued
- Mar 29, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(ii): Temporary wiring was not removed immediately upon completion of the project or purpose for which the wiring was installed: A. On or about January 25, 2017, Rear Wall of the Press Area: An orange flexible extension cord was run through a wall hole to power an electric leaf blower. The extension cord had been in place for more than 90 days and was not removed from service after the task was completed. The leaf blower was used in approximately October 2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Mar 29, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure A. On or about January 25, 2017, at the Forming Dies/Tools Rack: An orange flexible extension cord was used in lieu of the fixed wiring of the building to power a metal-encased desk lamp on a desk at the end of the rack. The extension cord was affixed to the metal rack with wire ties and black plastic electrical tape. B. In approximately October 2016, Rear of Building: An orange flexible extension cord was used in lieu of the fixed wiring of the building to power an electric leaf blower. The cord passed through a wall hole which accommodated a clothes dryer vent.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Mar 29, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: A. On or about January 25, 2017, Rear of Building: A flexible extension cord was run through a wall hole to the rear of the building. The cord had been used in lieu of the fixed wiring of the building to power an electric leaf blower in approximately October 2016.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 B
- Issued
- Mar 29, 2017
- Abate by
- May 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: A. On or about January 25, 2017, Shop: The Duracraft Drill Press, Model PD22-12, S/N 22886 was not securely anchored to the shop floor to prevent walking or moving during operation.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Satellite Aerospace, INC.
View Satellite Aerospace, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332116)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342048022.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.