ARLINGTON, TX —
OSHA Inspection: GENESEE PAINTING INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of GENESEE PAINTING INC. in SPRINGHILL SUITES 1975 E. LAMAR BLVD, ARLINGTON, TX 76006 (NAICS 238320). OSHA activity number 342050036.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GENESEE PAINTING INC.
- Site address
- SPRINGHILL SUITES 1975 E. LAMAR BLVD
- City
- ARLINGTON
- State
- TX
- ZIP
- 76006
- Mailing
- 8341 E. EVANS ROAD SUITE 106, SCOTTSDALE, AZ 85260
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238320
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Jan 25, 2017
- Abate by
- Feb 2, 2017
- Penalty
- Initial $1,630 · Current $978 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. On the south side of the building, employees working below employees above them were not protected from falling or flying materials by the use of protective helmets.
Recent events (2)
- — I (S) $978
- — Z (S) $1630
1926.405 A02 II I
- Issued
- Jan 25, 2017
- Abate by
- Feb 2, 2017
- Penalty
- Initial $2,716 · Current $1,630 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage. Employer failed to ensure an extension cord used to energize a portable compressor was protected from damage when ran through a metal frame window, exposing employees to electrical shock hazards.
Recent events (2)
- — I (S) $1629.6
- — Z (S) $2716
1926.453 B02 V
- Issued
- Jan 25, 2017
- Abate by
- Feb 2, 2017
- Penalty
- Initial $3,803 · Current $2,282 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift. Employees working from a "Sun Belt" aerial lift while performing painting activities on the south side of the hotel were not tied off and were not protected from a fall hazard of approximately 30 feet to the ground below.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.501 B01
- Issued
- Jan 25, 2017
- Abate by
- Feb 2, 2017
- Penalty
- Initial $3,803 · Current $2,282 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system. a) Employees performing painting activities on the awing on the south side of the hotel had no fall protection and were exposed to a fall hazard of more than 8 feet to the lower level. b) Employee performing painting activities on a low-sloped roof had no fall protection and were exposed to a fall hazard of approximately 30 feet to the lower level.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.1053 B01
- Issued
- Jan 25, 2017
- Abate by
- Feb 2, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. The employer failed to ensure that the Werner extension ladder on the south side of the hotel was extended at least 3 feet above the upper landing surface and secured for employees to gain access to the canopy exposing the employees to a fall hazard of approximately 8 feet to the ground below.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
More inspections at Genesee Painting INC.
View Genesee Painting INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238320)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342050036.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.