OSHA Inspection: THE INSULATION MAN, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of THE INSULATION MAN, LLC in 276 CORLISS AVE., JOHNSON CITY, NY 13790 (NAICS 238310). OSHA activity number 342050713.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Insulation MAN, LLC — free Get an email when a new federal OSHA severe-injury report for The Insulation MAN, LLC is published. One employer, no account, unsubscribe in one click.
Site address
276 CORLISS AVE.
City
JOHNSON CITY
State
NY
ZIP
13790
Mailing
428 COURT ST, BINGHAMTON, NY 13904
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
12
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 7 exposed
Issued
May 19, 2017
Abate by
Jun 13, 2017
Penalty
Initial $1,630 · Current $1,223 Reduced

Hazardous substances 1073

29 CFR 1910.134(c)(1)  Employer did not establish nor implement a written respiratory protection program with worksite specific procedures when respirators were necessary to protect the health of the employee or whenever respirators were required by the employer:      a)  On site, on or about 1/19/17: Employer had not established a written respirator protection program when employees were required to wear full face and half face air purifying respirators.
Recent events (2)
  • — I (S) $1222.5
  • — Z (S) $1630

1910.134 E01

Serious Gravity 1 1 instance 4 exposed
Issued
May 19, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1073

29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   Note:  The employer may discontinue an employees medical evaluations when the employee is no longer required to use a respirator.     a) On Site, on or about 1/19/17: Employees required to wear half face air purifying respirator had not been provided with a medical evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F02

Serious Gravity 1 1 instance 7 exposed
Issued
May 19, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1073

29 CFR 1910.134(f)(2):  Employer did not ensure that an employee using a tight fitting face piece respirator was fit tested prior to initial use of the respirator, whenever a different respirator face piece (size, style, model or make) was used, and at least annually thereafter:    a)  On site, on or about 1/19/17: Employees required to wear half face air purifying respirators and had not been fit tested.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K

Serious Gravity 1 1 instance 7 exposed
Issued
May 19, 2017
Abate by
Jun 13, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1073

29 CFR 1910.134(k)  The employer did not provide effective, comprehensive, understandable, and annual (or more often if necessary) training to employees who are required to use respirators:    a) On site, on or about 1/19/17: Employees required to wear full face and half face air purifying respirators and have not received respirator training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 2 exposed
Issued
May 19, 2017
Penalty
Initial $1,630 · Current $1,223 Reduced

Hazardous substances 1073

29 CFR 1910.1200(h)(1):  Employees were not provided information and training as specified in 29 CFR 1910.1200(h)(1) and (2) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:      a) Onsite, on or about 1/19/17:  Employees were exposed to hazardous chemicals such as, but not limited to: Corbond III-Side A and Corbond III-Side B containing including but not limited to: methylenediphenyl diisocyanate and diphenylmethanediisocyanate and were not provided information and training as specified in 29 CFR 1910.1200(h)(1) and (2).