OSHA Inspection: C&S EXTERIORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C&S EXTERIORS in SUB LOT 210-212, WESTLAKE, OH 44145 (NAICS 238160). OSHA activity number 342050911.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C&S Exteriors for free Get an email when a new federal OSHA severe-injury report for C&S Exteriors is published. One employer, no account, unsubscribe in one click.
Establishment
C&S EXTERIORS
Site address
SUB LOT 210-212
City
WESTLAKE
State
OH
ZIP
44145
Mailing
20400 QUARRY RD., WELLINGTON, OH 44090
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 1, 2017
Abate by
Feb 21, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  On or about January 25, 2017, during the installation of roofing material for a residential construction project, located at sub lot 210-212 Ashbourne Dr., Westlake, OH, the employer did not ensure employees working from a ladder jack type scaffold were protected from falling by a guardrail, personal fall arrest, or other fall protection system. The employees were working approximately 2 stories above the next lower level (ground).
Recent events (1)
  • · Z (S) $3803

1926.452 K05

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 1, 2017
Abate by
Feb 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.452(k)(5): Scaffold platforms were bridged on to another:  On or about January 25, 2017, during installation of roofing materials, the employer did not ensure employees were working from a ladder jack scaffold where scaffold platforms were not bridged one to another. The employees were working approximately 19 ft. above the ground.
Recent events (1)
  • · Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 1, 2017
Abate by
Feb 21, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   On or about January 25, 2017, during the installation of roofing material on a residential home, the employer did not ensure employees were protected from a fall hazard of approximately 19 feet by utilizing a guardrail system, safety new system, and/or other fall protection system or device.