SAINT CHARLES, IL —
OSHA Inspection: ARMOUR ECKRICH, LLC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ARMOUR ECKRICH, LLC. in 410 KIRK ROAD, SAINT CHARLES, IL 60174 (NAICS 311612). OSHA activity number 342055662.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMOUR ECKRICH, LLC.
- Site address
- 410 KIRK ROAD
- City
- SAINT CHARLES
- State
- IL
- ZIP
- 60174
- Mailing
- 410 KIRK ROAD, SAINT CHARLES, IL 60174
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311612
- Employees
- 290
- Ownership type
- A
Citations
1 citation on file for this inspection.
1910.119 D03 II
- Issued
- Jul 20, 2017
- Penalty
- Initial $6,157 · Current $6,157
General-duty citation text
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices: The employer did not document that the equipment complies with recognized and generally accepted good engineering practices in the following instances: (a) The following doors were not tight-fitting to prevent the migration of ammonia into other work areas in the event of a release: The interior door to the plant from Plant 1 (engine room) and the interior door to the plant from Plant 2 (engine room). These doors were missing door seals along the bottom of the door. Employees in the general plant areas would be exposed in the event of a significant ammonia release. The employer did not document compliance, for these doors, with recognized and generally accepted good engineering practices such as, but not limited to, ANSI/ASHRAE Standard 15 Safety Standard for Refrigeration Systems. (b) The employer did not document that the Water Chiller 2 in Plant 2, a pressure vessel, complied with applicable recognized and generally accepted good engineering practices such as, but not limited to, the ASME Boiler & Pressure Vessel Code, Section VII, Division 1, Rules for Construction of Pressure Vessels and IIAR Bulletin 109, Guidelines for IIAR Minimum Safety Criteria for a Safe Ammonia Refrigeration System, in that the vessel did not have a nameplate which identified the vessel with a National Board number and had the maximum allowable pressure and temperature stamped on it. CORRECTED DURING INSPECTION.
Recent events (2)
- — I (O) $6157
- — Z (S) $6157
More inspections at Armour Eckrich, LLC.
View Armour Eckrich, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 311612)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342055662.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.