Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARMOUR ECKRICH, LLC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ARMOUR ECKRICH, LLC. in 410 KIRK ROAD, SAINT CHARLES, IL 60174 (NAICS 311612). OSHA activity number 342055662.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Armour Eckrich, LLC. — free Get an email when a new federal OSHA severe-injury report for Armour Eckrich, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
410 KIRK ROAD
City
SAINT CHARLES
State
IL
ZIP
60174
Mailing
410 KIRK ROAD, SAINT CHARLES, IL 60174
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311612
Employees
290
Ownership type
A

1 citation on file for this inspection.

1910.119 D03 II

Other-than-serious Gravity 5 2 instances 3 exposed
Issued
Jul 20, 2017
Penalty
Initial $6,157 · Current $6,157
29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices:     The employer did not document that the equipment complies with recognized and generally accepted good engineering practices in the following instances:     (a) The following doors were not tight-fitting to prevent the migration of ammonia into other work areas in the event of a release:  The interior door to the plant from Plant 1 (engine room) and the interior door to the plant from Plant 2 (engine room).  These doors were missing door seals along the bottom of the door.  Employees in the general plant areas would be exposed in the event of a significant ammonia release.  The employer did not document compliance, for these doors, with recognized and generally accepted good engineering practices such as, but not limited to, ANSI/ASHRAE Standard 15 Safety Standard for Refrigeration Systems.     (b) The employer did not document that the Water Chiller 2 in Plant 2, a pressure vessel, complied with applicable recognized and generally accepted good engineering practices such as, but not limited to, the ASME Boiler & Pressure Vessel Code, Section VII, Division 1, Rules for Construction of Pressure Vessels and IIAR Bulletin 109, Guidelines for IIAR Minimum Safety Criteria for a Safe Ammonia Refrigeration System, in that the vessel did not have a nameplate which identified the vessel with a National Board number and had the maximum allowable pressure and temperature stamped on it.     CORRECTED DURING INSPECTION.
Recent events (2)
  • — I (O) $6157
  • — Z (S) $6157

View Armour Eckrich, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342055662.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.