MANSFIELD, MO —
OSHA Inspection: H CASTLE LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of H CASTLE LLC in 989 LUCKY ROAD, MANSFIELD, MO 65704 (NAICS 321214). OSHA activity number 342056207.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H CASTLE LLC
- Site address
- 989 LUCKY ROAD
- City
- MANSFIELD
- State
- MO
- ZIP
- 65704
- Mailing
- P.O. BOX 42, MANSFIELD, MO 65704
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321214
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 A01
- Issued
- Apr 24, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $3,803 · Current $1,902 Reduced
W103
General-duty citation text
29 CFR 1910.22(a)(1): The employer failed to provide a clean and sanitary condition for all places of employment, passageways, storerooms, service rooms, and walking-working surfaces. a) On or about January 25, 2017, the employer failed to keep working areas clean and free from accumulation of wood dust. Employees were exposed to serious fire and explosion hazards. Kst Test for explosibility of sampled wood dust measured 8.75 bar*meter/second, with a pressure ratio of 5.99 and 10% moisture content. The material is considered explosive. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (S) $1901.5
- — Z (S) $3803
1910.178 L01 I
- Issued
- Apr 24, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $2,716 · Current $1,358 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) On or about January 25, 2017, the employer failed to ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Employees were exposed to serious struck by hazards while working in areas where the Manitou fork truck (S/N T6020599) is operated. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (S) $1358
- — Z (S) $2716
1910.305 B02 I
- Issued
- Apr 24, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $3,803 · Current $1,902 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or about January 25, 2017, the employer failed to ensure that each outlet box had a cover, faceplate, or fixture canopy. Employees were exposed to serious fire and electrical shock hazards in the following instances: 1) An outlet box secured to the support pole located next to the wood-burning furnace lacked a cover or faceplate. This outlet was used to power portable fans. 2) An outlet box located under the fire extinguisher near the truss assembly area lacked a cover or faceplate. This outlet was used to power a battery charger for handheld power tools. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (2)
- — I (S) $1901.5
- — Z (S) $3803
1910.305 C04
- Issued
- Apr 24, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(c)(4): Faceplates for flush-mounted snap switches. Snap switches mounted in boxes shall have faceplates installed so as to completely cover the opening and seat against the finished surface. (a) On or about January 25, 2017, the employer failed to ensure that each snap switch mounted in a box has a faceplate installed so as to completely cover the opening and seat against the finished surface. A snap switch located between the facility door and truss assembly area lacked a faceplate. Employees were exposed to serious fire and electrical shock hazards. Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.