EDINBURG, TX —
OSHA Inspection: RENE PEREZ BARRERA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RENE PEREZ BARRERA in 2501 VANCOUVER AVE., EDINBURG, TX 78539 (NAICS 238140). OSHA activity number 342056587.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RENE PEREZ BARRERA
- Site address
- 2501 VANCOUVER AVE.
- City
- EDINBURG
- State
- TX
- ZIP
- 78539
- Mailing
- 5500 N. MCCOLL RD #D-PMB 183, MCALLEN, TX 78504
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 10
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01 I
- Issued
- Mar 17, 2017
- Penalty
- Initial $1,847 · Current $1,108 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. Employees conducted masonry work at the front of a residential construction from a scaffold platform that was not fully planked more than 10 feet above ground level.
Recent events (2)
- — I (S) $1108.2
- — Z (S) $1847
1926.451 C02
- Issued
- Mar 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: Employees conducted masonry work at the front of a residential construction from a scaffold that did not have base plates.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Mar 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: Employees conducted masonry work at the front of a residential construction from a scaffold, and a ladder was not provided for safe access.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 H02 II
- Issued
- Mar 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(h)(2)(ii): A toeboard was not erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below: Employees conducted masonry work at the front of a residential construction from a scaffold more than 10 feet above ground level that lacked toe boards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Mar 17, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Employees conducted masonry work at the front of a residential construction from a scaffold greater than 10 feet above ground level without fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342056587.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.