Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACQUEST CONSTRUCTION LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ACQUEST CONSTRUCTION LLC in 408 MILL STREET, WILLIAMSVILLE, NY 14221 (NAICS 236116). OSHA activity number 342059771.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acquest Construction LLC — free Get an email when a new federal OSHA severe-injury report for Acquest Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
408 MILL STREET
City
WILLIAMSVILLE
State
NY
ZIP
14221
Mailing
80 CURTWRIGHT DRIVE, SUITE 5, WILLIAMSVILLE, NY 14221
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.502 B03

Other-than-serious 1 instance 4 exposed
Issued
Jul 6, 2017
Penalty
Initial $3,803 · Current $2,000 Reduced
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:      a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY:  Temporary  wood guardrails were installed  along the two open sides of the decks/balconies  to protect workers from falls of approx.  11 ft.  from second story exterior decks /balconies to approx.  21 ft. 6 in. from third story exterior decks/balconies.   On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood  2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony,  one vertical wood  2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony.  Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members  to form the guardrail system .  The horizontal spans of the toprails and midrails on the outside end of the decks /balconies were approx.  11 feet  4 inches. The horizontal spans of the toprails and midrails on the east side of the unit  313 deck/balcony were approx.  9 feet 3 inches. The horizontal spans  on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies  were greater  than the 8 foot  span between vertical posts  recommended  for wooden guardrails in Appendix  B of  Subpart M of this standard.  Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies.  Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions.   An employee fell   21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony.          NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
  • — J (O) $2000
  • — C (S) $3803
  • — Z (S) $3803

1926.502 B05

Other-than-serious 1 instance 4 exposed
Issued
Jul 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members shall be capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward direction at any point along the midrail or other member:      a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY:  Temporary  wood guardrails were installed  along the two open sides of the decks/balconies  to protect workers from falls of approx.  11 ft.  from second story exterior decks /balconies to approx.  21 ft. 6 in. from third story exterior decks/balconies.   On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood  2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony,  one vertical wood  2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony.  Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members  to form the guardrail system .  The horizontal spans of the toprails and midrails on the outside end of the decks /balconies were approx.  11 feet  4 inches. The horizontal spans of the toprails and midrails on the east side of the unit  313 deck/balcony were approx.  9 feet 3 inches. The horizontal spans  on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies  were greater  than the 8 foot  span between vertical posts  recommended  for wooden guardrails in Appendix  B of  Subpart M of this standard.  Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies.  Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions.   An employee fell   21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony.          NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (3)
  • — J (O) $0
  • — C (S) $0
  • — Z (S) $0

View Acquest Construction LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342059771.