Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CMJ CONSTRUCTION SERVICES INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of CMJ CONSTRUCTION SERVICES INC. in 408 MILL STREET, WILLIAMSVILLE, NY 14221 (NAICS 238130). OSHA activity number 342061850.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CMJ Construction Services INC. — free Get an email when a new federal OSHA severe-injury report for CMJ Construction Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
408 MILL STREET
City
WILLIAMSVILLE
State
NY
ZIP
14221
Mailing
140 GARDEN VILLAGE DRIVE, APT. 3, CHEEKTOWAGA, NY 14227
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.502 B03

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 30, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:    a) On or about 1/11/17 on the second and third story exterior decks/balconies on the north and south sides , east of the center section, of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY:  Temporary  wood guardrails were installed  along the two open sides of the decks/balconies  to protect workers from falls of approx.  11 ft.  from second story exterior decks /balconies to approx.  21 ft. 6 in. from third story exterior decks/balconies. The guardrail system on the balconies consisted of one vertical 6 x 6 inch wood structural post , in an outward corner of the balcony, one vertical wood  2x 4 nailed into the wall of the mechanical room wall at an outward corner of the deck/balcony,  and one vertical wood  2x 4 nailed into the wall of the building at an inside corner of the deck/balcony.  Horizontal wood 2 x 4 toprails, and  horizontal wood 2 x 4 midrails were nailed into the vertical members  to form the guardrail system .  The horizontal spans of the toprails and midrails on the outside end  of the deck /balcony were approx.  11 feet  4 inches. The horizontal spans of the toprails and midrails on the east and west sides of the deck/balcony were approx.  9 feet 3 inches.  These horizontal spans  were greater  than the 8 ft . span between vertical posts  recommended  for wooden guardrails in Appendix  B of  Subpart M of this standard.      NO ABATEMENT DOCUMENTATIOM REQUIRED
Recent events (1)
  • — Z (S) $3803

1926.502 B05

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members were not capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward direction at any point along the midrail or other member:    a) On or about 1/11/17 on the second and third story exterior decks/balconies on the north and south sides , east of the center section, of a 3- story apartment building under construction at 408 Mill St., Williamsville, NY:  Temporary  wood guardrails were installed  along the two open sides of the decks/balconies  to protect workers from falls of approx.  11 ft.  from second story exterior decks /balconies to approx.  21 ft. 6 in. from third story exterior decks/balconies. The guardrail system on the balconies consisted of one vertical 6 x 6 inch wood structural post , in an outward corner of the balcony, one vertical wood  2x 4 nailed into the wall of the mechanical room wall at an outward corner of the deck/balcony,  and one vertical wood  2x 4 nailed into the wall of the building at an inside corner of the deck/balcony.  Horizontal wood 2 x 4 toprails, and  horizontal wood 2 x 4 midrails were nailed into the vertical members  to form the guardrail system .  The horizontal spans of the toprails and midrails on the outside end  of the deck /balcony were approx.  11 feet  4 inches. The horizontal spans of the toprails and midrails on the east and west sides of the deck/balcony were approx.  9 feet 3 inches.  These horizontal spans  were greater  than the 8 ft . span between vertical posts  recommended  for wooden guardrails in Appendix  B of  Subpart M of this standard.      NO ABATEMENT DOCUMENTATIOM REQUIRED
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342061850.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.