Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CHRISTMAS DESIGNERS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHRISTMAS DESIGNERS, INC. in 8551 COOPER CREEK BLVD., BRADENTON, FL 34201 (NAICS 541490). OSHA activity number 342065604.

Watch Christmas Designers, INC. — free Get an email when a new federal OSHA severe-injury report for Christmas Designers, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8551 COOPER CREEK BLVD.
City
BRADENTON
State
FL
ZIP
34201
Mailing
3124 NW 16TH TERRACE, POMPANO BEACH, FL 33064
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
541490
Employees
101
Ownership type
A

4 citations on file for this inspection.

1910.138 A

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 17, 2017
Abate by
Aug 18, 2017
Penalty
Initial $11,408 · Current $4,563 Reduced
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes:     (a) For employees using Altec bucket trucks while removing light strands from bottle brush trees located next to 138 kV overhead power lines while using rubber gloves, on or about January 25, 2017.
Recent events (2)
  • — I (S) $4563.2
  • — Z (S) $11408

1910.333 C03 I A 2

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 17, 2017
Abate by
Aug 31, 2017
Penalty
Initial $11,408 · Current $4,563 Reduced
29 CFR 1910.333(c)(3)(i)(A)(2): When an unqualified person was working in an elevated position near overhead lines with voltages to ground rated over 50 kv, the location was not such that the person and the longest conductive object he or she could contact would not come closer to any unguarded, energized overhead line than 10 feet (305 cm) plus 4 inches (10 cm) for every 10 kV over 50 kV:    (a) For employees removing Christmas lighting displays while using an Altec Aerial Bucket Truck set up near 138kv overhead power lines, on or about January 25, 2017.
Recent events (2)
  • — I (S) $4563.2
  • — Z (S) $11408

1910.333 C03 III B

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 17, 2017
Abate by
Aug 31, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(3)(iii)(B): Employees standing on the ground may not contact the vehicle or mechanical equipment or any of its attachments, unless: (1) the employees are using protective equipment rated for the voltage; or (2) the equipment is located so that no uninsulated part of its structure (that portion of the structure that provides a conductive path to employees on the ground) can come closer to the line than permitted in paragraph (c)(3)(iii) of this section:  (A)  For employees collecting light strands on the ground below two Altec T40 Aerial Bucket Trucks that were set up by 138kv overhead power lines, on or about January 25, 2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D02

Other-than-serious 1 instance 2 exposed
Issued
Jul 17, 2017
Abate by
Aug 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:    a)  For employees removing Christmas lighting displays, on or about January 25, 2017.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Christmas Designers, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342065604.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.