Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RELIABLE ROOFING SYSTEMS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RELIABLE ROOFING SYSTEMS, INC in 5216 PRAIRIE GRASS LANE, COLORADO SPRINGS, CO 80922 (NAICS 238160). OSHA activity number 342072030.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reliable Roofing Systems, INC — free Get an email when a new federal OSHA severe-injury report for Reliable Roofing Systems, INC is published. One employer, no account, unsubscribe in one click.
Site address
5216 PRAIRIE GRASS LANE
City
COLORADO SPRINGS
State
CO
ZIP
80922
Mailing
105 CATALINA PLACE, COLORADO SPRINGS, CO 80906
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Feb 3, 2017
Abate by
Feb 9, 2017
Penalty
Initial $3,622 · Current $1,000 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:    (a)  On or about February 1, 2017, employees were exposed to injuries resulting from falls, while working from a portable ladder that did not extend at least 3 feet above the upper landing surface being accessed.
Recent events (3)
  • — F (S) $1000
  • — C (S) $3622
  • — Z (S) $3622

1926.501 B13

Repeat Gravity 10 1 instance 4 exposed
Issued
Feb 3, 2017
Abate by
Feb 9, 2017
Penalty
Initial $27,885 · Current $14,754 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):     (a)  On or about February 1, 2017, employees were exposed to injuries from falls, while conducting reroofing activities, without the benefit of fall protection systems being in place, on a roof in excess of six feet above the lower surface.      Reliable Roofing Systems, Inc., was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard which was contained in OSHA Inspection Number 986664, Citation Number 1, Item Number 1, and was affirmed as a final order on August 13, 2014, with respect to a workplace located at 1701 S. Tejon Street, Colorado Springs, CO.    Reliable Roofing Systems, Inc., was previously cited for a violation of this Occupational Safety and Health standard or its equivalent standard which was contained in OSHA Inspection Number 982059, Citation Number 1, Item Number 1, and was affirmed as a final order on July 18, 2014, with respect to a workplace located at 512 San Miguel Street, Colorado Springs, CO.
Recent events (3)
  • — F (R) $14754
  • — C (R) $27885
  • — Z (R) $27885

View Reliable Roofing Systems, INC's full OSHA safety record →