Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: TEXAS PIPE FABRICATORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TEXAS PIPE FABRICATORS, INC. in 709 HIGH STARR DRIVE, CORPUS CHRISTI, TX 78408 (NAICS 332420). OSHA activity number 342076387.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Texas Pipe Fabricators, INC. — free Get an email when a new federal OSHA severe-injury report for Texas Pipe Fabricators, INC. is published. One employer, no account, unsubscribe in one click.
Site address
709 HIGH STARR DRIVE
City
CORPUS CHRISTI
State
TX
ZIP
78408
Mailing
P.O. BOX 9162, CORPUS CHRISTI, TX 78469
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332420
Employees
10
Ownership type
A

7 citations on file for this inspection.

1910.253 B02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 28, 2017
Penalty
Initial $2,463 · Current $1,150 Reduced
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:    In the shop, the oxygen cylinder stored adjacent to the shop bay door was not secured.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2463

1910.303 F02

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 28, 2017
Abate by
May 17, 2017
Penalty
Initial $2,173 · Current $1,150 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    At this establishment electrical panels did not have the circuit breakers marked as to their function and purpose.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2173

1910.303 G01

Serious Gravity 1 2 instances 2 exposed
Issued
Apr 28, 2017
Abate by
May 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  In the shop electrical panels and safety cutoff switches for multiple pieces of equipment were blocked.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 28, 2017
Abate by
May 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  In the shop at this establishment employees were exposed to electrical shock due to knockouts being removed from the cover of an electrical distribution breaker panel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 A02

Other-than-serious 1 instance 2 exposed
Issued
Apr 28, 2017
Abate by
May 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(a)(2): Acetylene used in an oxygen-fuel gas system was generated, piped or utilized at a pressure in excess of 15 psig (103 kPa gauge pressure) or 30 psia (206 kPa absolute):  At this establishment, employees welded using an oxygen-acetylene setup.  The acetylene cylinder was operated at pressures greater than 15 psig.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 28, 2017
Abate by
May 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1)(i): The written hazard communication program did not include a list of the hazardous chemicals known to be present, using an identity that was referenced on the appropriate material safety data sheet:  At this establishment the hazard communication program did not contain a separate list of the hazardous materials/chemicals, including, but not limited to, Sherwin Williams Reducer No. 15 (R7K15), Seymour Hi-Tech Gloss Safety Yellow spray paint, Lincoln Electric Excalibur 11018M MR welding rods, and Lincoln Electric Shield-Arc 70+ welding rods, present on site that employees used performing machine shop activities.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 4 instances 2 exposed
Issued
Apr 28, 2017
Abate by
May 10, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): The employer did not have a material safety data sheet for each hazardous chemical in use:  At this establishment employees involved in machine shop activities were exposed to hazardous materials.  The employer did not maintain Safety Data Sheets for each chemical employees use, including, but not limited to:  a.  Sherwin Williams Reducer No. 15 (R7K15), b.  Seymour Hi-Tech Gloss Safety Yellow spray paint, c.  Lincoln Electric Excalibur 11018M MR, and d.  Lincoln Electric Shield-Arc 70+.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Texas Pipe Fabricators, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342076387.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.