LAKEWOOD, NJ —
OSHA Inspection: M & JJ GENERAL CONSTRUCTION CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M & JJ GENERAL CONSTRUCTION CORPORATION in 315 MONMOUTH AVENUE, LAKEWOOD, NJ 08701 (NAICS 238140). OSHA activity number 342081288.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M & JJ GENERAL CONSTRUCTION CORPORATION
- Site address
- 315 MONMOUTH AVENUE
- City
- LAKEWOOD
- State
- NJ
- ZIP
- 08701
- Mailing
- 156 HIGH STREET, CARTERET, NJ 07008
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B01
- Issued
- Mar 2, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $3,803 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a- 315 Monmouth Avenue, Lakewood NJ: Employees, not supplied with fall protection, were exposed to fall hazards in excess of 26 feet to the ground surface below when performing EIFS preparation and other masonry related activities from a prefabricated, tubular welded framed scaffold whose walking/working surface was not fully planked. Condition observed on or about 02/06/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $2500
- — Z (S) $3803
1926.454 A
- Issued
- Mar 2, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a- 315 Monmouth Avenue, Lakewood NJ: Employees, not supplied with fall protection, were exposed to fall hazards in excess of 26 feet to the ground surface below when performing EIFS preparation and other masonry related activities from the top buck of a prefabricated, tubular welded framed scaffold that was missing guardrails, was not fully planked, contained damaged and mixed components, was missing safe access/egress from the walking/working level, etc. In addition the worksite company employees had not received any scaffold hazard recognition and minimization training, that meets with the requirements of the standard, from the company. Condition observed on or about 02/06/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E06 VI
- Issued
- Mar 2, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(6)(vi): Integral prefabricated scaffold access frames being used for access had a spacing greater than 16 3/4 inches. a- 315 Monmouth Avenue, Lakewood NJ: Employees, not supplied with fall protection, were exposed to fall hazards in excess of 26 feet to the ground surface below when accessing and egressing the walking/working surface of a prefabricated, tubular, welded framed scaffold using openings on the scaffold's frames. These openings had a vertical distance greater than 16 3/4 inches apart. Condition observed on or about 02/06/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F03
- Issued
- Mar 2, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $2,716 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a- 315 Monmouth Avenue, Lakewood NJ: Employees, not supplied with fall protection, were exposed to fall hazards in excess of 26 feet to the ground surface below when performing EIFS preparation and other masonry related activities from the top buck of a prefabricated, tubular welded framed scaffold system that contained damaged components. This scaffold was not inspected by a competent person. Condition observed on or about 02/06/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $1800
- — Z (S) $2716
1926.451 F04
- Issued
- Mar 2, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(4): Part(s) of a scaffold that were damaged or weakened, such that the scaffold's strength was less than that required by paragraph (a) of this section, were not immediately repaired, replaced, braced to meet those provisions, nor removed from service until repaired. a- 315 Monmouth Avenue, Lakewood NJ: Employees, not supplied with fall protection, were exposed to fall hazards in excess of 26 feet to the ground surface below when performing EIFS preparation and other masonry related activities from the top buck of a prefabricated, tubular welded framed scaffold system that contained visibly damaged cross braces and end frames. Condition observed on or about 02/06/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F07
- Issued
- Mar 2, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a- 315 Monmouth Avenue, Lakewood NJ: Employees, not supplied with fall protection, were exposed to fall hazards in excess of 26 feet to the ground surface below when performing EIFS preparation and other masonry related activities from the top buck of a prefabricated, tubular welded framed scaffold system that was missing guardrails, was not fully planked, contained damaged and mixed components, was missing safe access/egress from the walking/working level, etc. As such this scaffod system was not erected under the supervision of a trained, competent person. Condition observed on or about 02/06/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01 VII
- Issued
- Mar 2, 2017
- Abate by
- May 30, 2017
- Penalty
- Initial $3,803 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a- 315 Monmouth Avenue, Lakewood NJ: Employees, not supplied with fall protection, were exposed to fall hazards in excess of 26 feet to the ground surface below when performing EIFS preparation and other masonry related activities from the top buck of a prefabricated, tubular welded framed scaffold that was missing guardrails. Condition observed on or about 02/06/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $2500
- — Z (S) $3803
More inspections in this industry (NAICS 238140)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342081288.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.