Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & A DUENAS CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J & A DUENAS CONSTRUCTION, LLC in 2611 HARTFIELD LN, MASON, OH 45040 (NAICS 238130). OSHA activity number 342081700.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & a Duenas Construction, LLC — free Get an email when a new federal OSHA severe-injury report for J & a Duenas Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
2611 HARTFIELD LN
City
MASON
State
OH
ZIP
45040
Mailing
9261 FIELDS DR., MASON, OH 45040
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
8
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 23, 2017
Abate by
Mar 1, 2017
Penalty
Initial $4,183 · Current $4,183
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  Located along the front porch stud framed top plate of the residential structure an employee is observed performing truss erection associated activities adjacent to unprotected perimeter exterior sides or edges of the top plate and unprotected areas of the interior lower cord of the truss without conventional fall protection systems and was exposed to fall potentials in excess of 11 feet.
Recent events (1)
  • — Z (S) $4183

1926.1053 B06

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 23, 2017
Abate by
Mar 1, 2017
Penalty
Initial $3,585 · Current $3,585
29 CFR 1926.1053(b)(6): Ladders shall be used only on stable and level surfaces unless secured to prevent accidental displacement.  Located along the residential interior stud framed porch an employee accessed stud framed truss and top plate areas utilizing an approximate 6 foot blue Werner step ladder laid folded flat against an exterior porch wall with the ladder top directly below the porch truss lower cord. The ladder is not secured from being displaced and is base supported by the lower portion bottom ladder rung setting flat and straddling an approximate 2X8 framing board without any of the ladders feet surface being supported exposing the ladder to becoming displaced and an employee fall potential in excess of 6 foot.
Recent events (1)
  • — Z (S) $3585

View J & a Duenas Construction, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342081700.