Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PEMCO, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of PEMCO, INC. in 150 PORTAGE ROAD, NIAGARA FALLS, NY 14303 (NAICS 325188). OSHA activity number 342083425.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pemco, INC. — free Get an email when a new federal OSHA severe-injury report for Pemco, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
PEMCO, INC.
Site address
150 PORTAGE ROAD
City
NIAGARA FALLS
State
NY
ZIP
14303
Mailing
150 PORTAGE ROAD, NIAGARA FALLS, NY 14303
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
20
Ownership type
A

3 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 17, 2017
Abate by
May 18, 2017
Penalty
Initial $4,346 · Current $2,160 Reduced
29 CFR 1910.95(c)(1):  A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8 hour time-weighted average sound level (TWA) of 85 dBA:       a) Crusher Area- On or about 02/13/2017, employees were exposed to continuous noise level at 85.6% and 122% of the permissible daily noise level (8 hour time-weighed average sound level of 90 dBA) or equivalent time-weighted of approximately 88.9 dBA and 91.0 using the 80 dBA threshold level.  The employer has not instituted a hearing conservation program.       A hearing conservation program should include descriptions of how the criteria for the following are addressed:          1.  Are there areas in the workplace where continuous noise levels exceed 85 decibels?;         2.  Is there an ongoing preventive health program to educate employees in safe levels of noise, exposures, effects of noise on their health and the use of personal protection?;         3.  Have engineering controls been used to reduce excessive noise levels? Where engineering controls are determined to be infeasible, are administrative controls (i.e., worker rotation) being used to minimize individual employee exposure to noise?;         4.  Is approved hearing protective equipment (noise attenuating devices) available to every employee working in noisy areas?;         5.  Has noisy machinery been isolated from the rest of your operation?         6.  If employees use hearing protection, are employees properly fitted and instructed in their use?; AND         7.  The general requirements of this section.              ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $2160
  • — C (S) $4346
  • — Z (S) $4346

1910.219 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 17, 2017
Penalty
Initial $2,897 · Current $1,440 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    a) Roll crusher - On or about 2/07/17, Conveyor belts on drive system for Crusher-Sturtevant serial #D147868, and Exolon serial #N566-B6096 was unguarded.    NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $1440
  • — C (S) $2897
  • — Z (S) $2897

1910.219 E03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  a) Roll crusher - On or about 2/07/17, Conveyor V-belt on drive system for Crusher-Sturtevant serial #D147868, and Exolon serial #N566-B6096 was unguarded.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

View Pemco, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342083425.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.