Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MANHEIM EL PASO AUTO AUCTION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of MANHEIM EL PASO AUTO AUCTION in 485 COATES, EL PASO, TX 79932 (NAICS 423110). OSHA activity number 342090420.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Manheim EL Paso Auto Auction — free Get an email when a new federal OSHA severe-injury report for Manheim EL Paso Auto Auction is published. One employer, no account, unsubscribe in one click.
Site address
485 COATES
City
EL PASO
State
TX
ZIP
79932
Mailing
485 COATES, EL PASO, TX 79932
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423110
Employees
1700
Ownership type
A

7 citations on file for this inspection.

1910.110 F02 I

Serious Gravity 1 1 instance 10 exposed
Issued
May 23, 2017
Abate by
May 30, 2017
Penalty
Initial $5,432 · Current $4,000 Reduced
29 CFR 1910.110(f)(2)(i): Containers in storage were not located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.    On February 08, 2017, the employer was storing propane cylinders in the fire cabinet.  This condition exposed employees to fire hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5432

1910.305 G01 IV C

Serious Gravity 5 2 instances 5 exposed
Issued
May 23, 2017
Abate by
Jun 5, 2017
Penalty
Initial $9,054 · Current $4,000 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.      On February 08, 2017, employees were exposed to electrical shock hazards in the following instances:      a)  Inside the guard shack of the vehicle storage yard, employees were using electrical equipment that was not in accordance with instructions included in the listing or labeling.      b) Inside the radio charging room, employees were using electrical equipment that was not in accordance with instructions included in the listing or labeling.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $9054

1910.303 G02 I D

Serious Gravity 1 2 instances 10 exposed
Issued
May 23, 2017
Abate by
Jun 5, 2017
Penalty
Initial $5,432 · Current $4,000 Reduced
29 CFR 1910.303(g)(2)(i)(D): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by elevation of 8 feet or more above the floor or other working surface.    On February 08, 2017, employees working in the wash bay were working near live florescent light fixtures that were not covered and were not 8 feet above the working surface.  This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5432

1910.305 G01 IV C

Serious Gravity 1 1 instance 5 exposed
Issued
May 23, 2017
Abate by
Jun 5, 2017
Penalty
Initial $5,432 · Current $4,000 Reduced
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through doorways, windows, floors, or similar openings.    On February 08, 2017, employees were working near an extension cord that was run through a door way.  This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5432

1910.305 G01 IV A

Serious Gravity 1 1 instance 5 exposed
Issued
May 23, 2017
Abate by
Jun 5, 2017
Penalty
Initial $5,432 · Current $4,000 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.    On February 08, 2017, employees were using flexible cords as a substitute for fixed wiring.  This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5432

1910.334 A03 I

Serious Gravity 1 1 instance 3 exposed
Issued
May 23, 2017
Abate by
May 30, 2017
Penalty
Initial $5,432 · Current $4,000 Reduced
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor.    On February 08, 2017, employees were using a flexible cord to charge a battery pack that did not contain a grounding conductor. This condition exposed employees to electrical shock hazards.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $5432

1910.1200 A01

Other-than-serious 4 instances 5 exposed
Issued
May 23, 2017
Abate by
Jun 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(a)(1): The employer did not effectively ensure that the information concerning the hazards of all chemicals  to which the employees may be exposed to, was transmitted as accomplished by the means of the employer's comprehensive hazard communication programs including labeling and other forms of warning, material safety data sheets and employee training.  On February 08, 2017, the employer did not ensure that all chemical containers in the workplace were properly labeled in accordance with OSHA's Hazard Communication Standard.  This condition exposed employee to health hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Manheim EL Paso Auto Auction's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342090420.