MILWAUKEE, WI —
OSHA Inspection: TRAMONT MANUFACTURING LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of TRAMONT MANUFACTURING LLC in 3701 NORTH HUMBOLDT BOULEVARD, MILWAUKEE, WI 53212 (NAICS 332420). OSHA activity number 342091634.
Where did this inspection happen?
- Establishment
- TRAMONT MANUFACTURING LLC
- Site address
- 3701 NORTH HUMBOLDT BOULEVARD
- City
- MILWAUKEE
- State
- WI
- ZIP
- 53212
- Mailing
- 3701 NORTH HUMBOLDT BOULEVARD, MILWAUKEE, WI 53212
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 140
- Ownership type
- A
Citations
6 citations on file for this inspection.
1903.19 D01
- Issued
- Abate by
- Penalty
- Initial $914.00 · Current $914.00
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required. (a) The employer failed to provide documentation to the Agency demonstrating that abatement is completed for the serious violation that was issued by the Agency.
Recent events (1)
- — Z (O) $914
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $4889.00 · Current $4889.00
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) The exit door on the east side of the welding bays was cordoned off with Caution tape, two concrete exit stair treads were broken and the exit door at the bottom of the same stair well was locked.
Recent events (1)
- — Z (S) $4889
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $6519.00 · Current $6519.00
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) There was no written respiratory protection program implemented for employees such as the welders and the painters that wear air-supplied welding respirators, negative pressure half-mask respirators and loose fitting hood supplied air painting respirators.
Recent events (1)
- — Z (S) $6519
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) The painter using the supplied air respirator (loose-fitting hood) did not have a current medical approval. (b) The welders using the powered air purifying respirators did not have current medical approvals. (c) The welders using the negative pressure respirators did not have current medical approvals.
Recent events (1)
- — Z (S) $0
1910.304 G05
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: (a) The ground conductor pin was broken off of the electrical plug for the cord and plug connected electric hoist used in the large welding bay.
Recent events (1)
- — Z (O) $0
1910.334 A02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): (a) In the welding area the damaged electrical extension cord had a taped repair and had not been removed from service.
Recent events (1)
- — Z (O) $0
More inspections at TRAMONT MANUFACTURING LLC
MILWAUKEE, WI—2023-03-06 00:00:00
TRAMONT MANUFACTURING LLC
MILWAUKEE, WI—2023-03-06 00:00:00
TRAMONT MANUFACTURING LLC
MILWAUKEE, WI—2021-01-11 00:00:00
TRAMONT MANUFACTURING LLC
MILWAUKEE, WI—2021-01-11 00:00:00
TRAMONT MANUFACTURING LLC
MILWAUKEE, WI—2020-02-14 00:00:00
TRAMONT MANUFACTURING LLC
View TRAMONT MANUFACTURING LLC's full OSHA safety record →
More inspections in this industry (NAICS 332420)
WRENS, GA—2026-07-08
LEWIS STEEL WORKS, INC.
THEODORE, AL—2026-06-25
CHART INDUSTRIES, INC.
BALL GROUND, GA—2026-06-09
CHART INDUSTRIES
ROLAND, OK—2026-06-02
PITTSBURG TANK & TOWER
ODESSA, TX—2026-05-26
P2 CONSTRUCTION INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342091634.