OKLAHOMA CITY, OK —
OSHA Inspection: CUSTOM CUTTING MILLWORKS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CUSTOM CUTTING MILLWORKS, INC. in 3905 AMELIA AVENUE, OKLAHOMA CITY, OK 73112 (NAICS 321918). OSHA activity number 342094570.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM CUTTING MILLWORKS, INC.
- Site address
- 3905 AMELIA AVENUE
- City
- OKLAHOMA CITY
- State
- OK
- ZIP
- 73112
- Mailing
- 3905 AMELIA AVENUE, OKLAHOMA CITY, OK 73112
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321918
- Employees
- 11
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.213 C01
- Issued
- May 22, 2017
- Abate by
- Jun 7, 2017
- Penalty
- Initial $4,346 · Current $2,608 Reduced
General-duty citation text
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut: On or about February 8, 2017, Delta circular ripsaw was not guarded by an automatically adjusting hood. Employees were exposed to the hazard of being struck by saw blade.
Recent events (2)
- — I (S) $2607.6
- — Z (S) $4346
1910.213 C02
- Issued
- May 22, 2017
- Abate by
- Jun 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(2): Hand-fed circular ripsaw(s) were not furnished with a spreader to prevent material from squeezing the saw or being thrown back on the operator: On or about February 8, 2017, Delta circular ripsaw was not furnished with a spreader. Employees were exposed to the hazard of being struck by lumber.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 C03
- Issued
- May 22, 2017
- Abate by
- Jun 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.213(c)(3): Hand-fed ripsaw(s) did not have non kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: On or about February 8, 2017, Delta circular ripsaw did not have non kickback fingers to prevent material from being thrown back toward operator. Employees were exposed to the hazard of being struck by lumber.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.213 N03
- Issued
- May 22, 2017
- Abate by
- Jun 7, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.213(n)(3): Hood(s) or suitable guard(s) were not provided to prevent the hands of the operator from coming in contact with the inrunning feed rolls on molder: On or about February 8, 2017, hood covering inrunning feed rolls on the molder had been removed. Employees were exposed to the hazard of being caught in inrunning nip point.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.305 B01 II
- Issued
- May 22, 2017
- Abate by
- Jun 7, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about February 8, 2017, electrical junction box located on grinder had unused openings that were not closed. Employees were exposed to the hazard of electric shock and/or fires.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.305 B02 I
- Issued
- May 22, 2017
- Abate by
- Jun 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about February 8, 2017, electrical junction box located on grinder was not provided with a cover. Employees were exposed to the hazard of electric shock and/or fires.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H02
- Issued
- May 22, 2017
- Abate by
- Jun 7, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(2): 1910.1200(h)(2): The employer did not provide information to employees on the requirements of the hazard communication standard, such as, but not limited to, the 2012 revised standard requirements. On or about February 8, 2017, the employer did not provide information to employees on the requirements of the hazard communication standard, such as, but not limited to, the 2012 revised standard requirements and training on new pictogram system.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Custom Cutting Millworks, INC.
View Custom Cutting Millworks, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321918)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342094570.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.