Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GLOBAL CERAMIC SERVICES INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GLOBAL CERAMIC SERVICES INC. in 125 PENCE ROAD, COWANSVILLE, PA 16218 (NAICS 332999). OSHA activity number 342095411.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Global Ceramic Services INC. — free Get an email when a new federal OSHA severe-injury report for Global Ceramic Services INC. is published. One employer, no account, unsubscribe in one click.
Site address
125 PENCE ROAD
City
COWANSVILLE
State
PA
ZIP
16218
Mailing
238 NORTH PARK DRIVE, KITTANNING, PA 16201
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
4
Ownership type
A

8 citations on file for this inspection.

1910.132 A

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 9, 2017
Abate by
Apr 4, 2017
Penalty
Initial $3,803 · Current $1,900 Reduced
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact:    (a) Facility, 125 Pence Road, Cowansville, PA:  On or about January 31, 2017 there was no protective shield or barrier provided around the melt off tank that contained 180 degree water to prevent employees from having contact or falling into the tank while using the hoist to set/remove parts exposing them to burn hazards.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3803

1910.212 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $2,716 · Current $1,360 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Facility, 125 Pence Road, Cowansville, PA:  On or about February 10, 2017 there were no guards in place on the unused portion of the blade on the horizontal band saw.  The saw is used by employees to cut cardboard.
Recent events (2)
  • — I (S) $1360
  • — Z (S) $2716

1910.213 C01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $2,716 · Current $1,360 Reduced
29 CFR 1910.213(c)(1): Circular handfed ripsaw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:    (a) Facility, 125 Pence Road, Cowansville, PA:  On or about February 10, 2017 the 10" table saw used to rip wood did not have a guard in place.  The saw is used by employees to rip wooden boards to make crates.
Recent events (2)
  • — I (S) $1360
  • — Z (S) $2716

1910.213 S06

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 9, 2017
Abate by
Mar 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(s)(6): Cleanliness around working machinery was not maintained to prevent fire hazards and ensure the effective functioning of guards:  (a) Facility, 125 Pence Road, Cowansville, PA:  On or about February 10, 2017 excessive amounts of wood dust accumulated in the motor area of the table saw and was not kept clean to prevent potential fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 H01

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 9, 2017
Abate by
Mar 21, 2017
Penalty
Initial $2,716 · Current $1,500 Reduced
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the material being cut:    (a) Facility, 125 Pence Road, Cowansville, PA:  There was no guard in place on the lower portion of the radial saw blade.  The saw is used by employees to cut wood that is used to build shipping crates and forms.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2716

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Mar 9, 2017
Penalty
Initial $2,716 · Current $1,220 Reduced
29 CFR 1904.39(a)(2): Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, the employer did not report the in-patient hospitalization, amputation, or loss of an eye to OSHA:    (a) Facility, 125 Pence Road, Cowansville, PA:  On or about January 31, 2017 an employee sustained 2nd and 3rd degree burns that resulted in an in-patient hospitalization.  The employer did not report the hospitalization to OSHA until   February 8, 2017.
Recent events (2)
  • — I (O) $1220
  • — Z (O) $2716

1910.147 C01

Other-than-serious 1 instance 3 exposed
Issued
Mar 9, 2017
Abate by
Apr 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a) Facility, 125 Pence Road, Cowansville, PA:  On or about February 10, 2017 the employer did not establish an energy control program that included employee training, energy control procedures and periodic inspections.  Employees service equipment such as but not limited to: bender(s), crane(s), and saw(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 3 exposed
Issued
Mar 9, 2017
Abate by
Apr 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  (a) Facility, 125 Pence Road, Cowansville, PA:  On or about February 10, 2017 the employer had not developed or implemented a written hazard communication program that addressed the criteria of labeling, maintaining safety data sheets or employee training.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342095411.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.