Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DHILLON TRANSPORT, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DHILLON TRANSPORT, INC. in 7307 YOUNG DRIVE UNIT 6, WALTON HILLS, OH 44146 (NAICS 488210). OSHA activity number 342101599.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dhillon Transport, INC. — free Get an email when a new federal OSHA severe-injury report for Dhillon Transport, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7307 YOUNG DRIVE UNIT 6
City
WALTON HILLS
State
OH
ZIP
44146
Mailing
7307 YOUNG DRIVE UNIT 6, WALTON HILLS, OH 44146
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488210
Employees
18
Ownership type
A

10 citations on file for this inspection.

1910.242 A

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jul 18, 2017
Abate by
Aug 11, 2017
Penalty
Initial $5,070 · Current $0 Reduced
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition:  On February 08, 2017, while in the process of servicing the air brakes of a trailer, an employee using a pneumatic brake tool (with compressed air set at 175 PSI) sustained a crushing injury when the adapter he placed into the spring side of the chamber failed to reduce the air pressure and caused the cage bolt inside of the brake chamber to come down catching the employees finger between the brake parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5070

1910.242 B

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 18, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $2,900
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      On or about February 13,2017, compressed air used by employees for cleaning purposes was set at 119 PSI.
Recent events (2)
  • — I (S) $2900
  • — Z (S) $0

1910.157 C04

Deleted Serious Gravity 1 2 instances 18 exposed
Issued
Jul 18, 2017
Penalty
Initial $2,173 · Current $0 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:   On or about February 13, 2017, two portable (ABC) fire extinguishers located on the north and east walls of the bay area were not fully charged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2173

1910.157 E01

Deleted Serious Gravity 1 1 instance 18 exposed
Issued
Jul 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace:    On or about February 13,2017, the employer did not maintain portable fire extinguishers at the workplace, as demonstrated by the two portable fire extinguishers located in the bay area that were not fully charged.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G02

Serious Gravity 1 1 instance 4 exposed
Issued
Jul 18, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $1,035
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  Note:  Applies where all employees are expected to fight fires.    On or about February 13, 2017, employees working in the maintenance/service bay of the facility were not trained  on fire extinguisher use for incipient stage fires on an annual basis.    a)  Note the employer may exercise one of the following options:     1. Provide portable fire extinguishers as specified in 29 CFR 1910.157(c)(1), meet the distribution requirements per 29 CFR 1910.157(d) (75 to the nearest extinguisher for Class A fires and 50 to the nearest unit for Class B fires), and provide training and education for all employees in the use of such equipment and the hazards associated with incipient stage fire fighting as specified in 29 CFR 1910.157(g).  The other sections of 29 CFR also apply.     2. Provide extinguishers as specified in 29 CFR 1910.157(c)(1), designate certain employees to be the only employees authorized to use such equipment and require all other employees to immediately evacuate upon the sound of the fire alarm, establish this in writing in an emergency action plan as outlined in 29 CFR 1910.38(a) and train/educate designated employees per 1910.157(g).  Utilizing this option exempts the employer from distribution requirements of 29 CFR 1910.157(d).     3. Establish a written fire safety policy which requires the immediate and total evacuation of employees from the workplace upon the sounding of a fire alarm signal.  This policy shall include an emergency action plan and a fire prevention plan as specified in 29 CFR 1910.38(a) and 29 CFR 1910.39(a).  Utilizing this option exempts the employer from the requirements of 29 CFR 1910.157 to include the need for providing portable fire equipment unless a specific standard requires that a portable fire extinguisher be provided (such as those requirements in 29 CFR 1910.106/107 related to the use/storage of flammable/combustible liquids).  If extinguishers are provided, but not intended for employee use, 29 CFR 1910.157(e) and (f) are still applicable (inspection, maintenance, and testing of equipment).
Recent events (2)
  • — I (S) $1035
  • — Z (S) $0

1910.219 D01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jul 18, 2017
Abate by
Aug 11, 2017
Penalty
Initial $2,173 · Current $0 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  On or about February 13, 2017, the drive pulley for the motor that runs the air compressor, located on the south wall of the bay area, was not guarded and thus potentially exposed employees to caught-in and/or struck-by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2173

1910.1200 E01

Serious Gravity 1 1 instance 18 exposed
Issued
Jul 18, 2017
Abate by
Sep 15, 2017
Penalty
Initial $2,173 · Current $1,035 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:         The employer did not develop, implement, or maintain a written hazard communication program at the site. Chemicals used at the site include but are not limited; motor oil, brake fluid, Aliphatic Petroleum Distillates (Common Name: WD-40) and compressed gases (Acetylene, Oxygen) etc.
Recent events (2)
  • — I (S) $1035
  • — Z (S) $2173

1910.1200 H01

Serious Gravity 1 1 instance 18 exposed
Issued
Jul 18, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:         Employees were not trained on the hazardous chemicals utilized in the workplace. Chemicals used at the site include; but are not limited to, motor oil, brake fluid, Aliphatic Petroleum Distillates (Common Name: WD-40) and compressed gases (Acetylene, Oxygen) etc.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 IV

Serious Gravity 1 1 instance 18 exposed
Issued
Jul 18, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(3)(iv): The employer did not train employees regarding the new label elements and safety data sheets format.    On or about February 13, 2017, the employer failed to provide training or information to employees working with hazardous chemicals on the details of outline in the new hazard communication standard which encompasses the Global Harmonization System (GHS).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.28 B08 II

Other-than-serious 1 instance 18 exposed
Issued
Jul 18, 2017
Abate by
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.28(b)(8)(ii): Floor markings at least 6 feet (1.8 m) from the edge of the pit were not in colors that contrast with the surrounding area and a warning line at least 6 feet (1.8 m) from the edge of the pit as well as stanchions were not in place.       On or about February 13, 2017, floor markings used to warn of danger, and stanchions were not located 6ft. from the edge of the service pit.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342101599.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.