TENAFLY, NJ —
OSHA Inspection: KL ROOFING & SIDING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KL ROOFING & SIDING in 2 INNES RD, TENAFLY, NJ 07670 (NAICS 238170). OSHA activity number 342102324.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KL ROOFING & SIDING
- Site address
- 2 INNES RD
- City
- TENAFLY
- State
- NJ
- ZIP
- 07670
- Mailing
- 18 TELSAR LANE, WARWICK, NY 10990
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 B01
- Issued
- Mar 3, 2017
- Penalty
- Initial $3,423 · Current $3,423
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) Exterior of Building - Scaffold Rear Facade: Employee engaged in siding activities from a welded frame scaffold that was not fully planked and exposed to fall hazards of approximately 12 feet in height, on or about 1/5/17.
Recent events (1)
- — Z (S) $3423
1926.451 E01
- Issued
- Mar 3, 2017
- Penalty
- Initial $3,423 · Current $3,423
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Exterior of Building - Scaffold Rear Facade: Employee was exposed to fall hazards of approximately 12 feet while engaged in siding activities from a welded frame scaffold that did not have a proper means of access, on or about 1/5/17.
Recent events (1)
- — Z (S) $3423
1926.451 F14
- Issued
- Mar 3, 2017
- Penalty
- Initial $3,423 · Current $3,423
General-duty citation text
29 CFR 1926.451(f)(14): Makeshift devices, such as boxes and barrels were used on top of scaffold platforms to increase the working level height of employees. a) Exterior of Building - Scaffold Rear. Facade: Employee was exposed to fall hazards of approximately 12 feet while standing on a bucket used to increase the height of a welded frame scaffold platform, on or about 1/5/17.
Recent events (1)
- — Z (S) $3423
More inspections at KL Roofing & Siding
View KL Roofing & Siding's full OSHA safety record →
More inspections in this industry (NAICS 238170)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342102324.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.