BOISE, ID —
OSHA Inspection: QUALITY THERMISTOR, INC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of QUALITY THERMISTOR, INC in 2108 CENTURY WAY, BOISE, ID 83709 (NAICS 334513). OSHA activity number 342102530.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY THERMISTOR, INC
- Site address
- 2108 CENTURY WAY
- City
- BOISE
- State
- ID
- ZIP
- 83709
- Mailing
- 2108 CENTURY WAY, BOISE, ID 83709
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334513
- Employees
- 40
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 D01 III
- Issued
- Jul 13, 2017
- Abate by
- Aug 8, 2017
- Penalty
- Initial $5,387 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (a) Kiln room: On and before February 13, 2017 a respiratory hazard exposure assessment was not completed for employees mixing various powdered production constituents, such as but not limited to: manganese oxide, iron oxide, titanium oxide, copper oxide, nickel oxide, and nickel and copper carbonate. (b) Spray room: On and before February 13, 2017 a respiratory hazard exposure assessment was not completed for employees exposed to volatile organic compounds and airborne metals such as silver and gold Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $3000
- — Z (S) $5387
1910.134 F01
- Issued
- Jul 13, 2017
- Abate by
- Aug 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (a) Throughout facility: On and before February 13, 2017 employees required to wear tight fitting respirators such as North half-face elastomeric respirators, were not fit tested prior to use by employees. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Jul 13, 2017
- Abate by
- Aug 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (a) Kiln room: On and before February 13, 2017 respirators were stored in a manner that would not protect them from potential contamination from manganese oxide, iron oxide, titanium oxide, copper oxide, nickel oxide, and nickel and copper carbonate. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 D02
- Issued
- Jul 13, 2017
- Abate by
- Aug 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: (a) Kiln room: On and before February 13, 2017 initial exposure data was not collected for employees using solder containing lead. (c) Production floor: On and before February 13, 2017 initial exposure data was not collected for employees using solder pots with soldering materials containing lead. Note: Abatement certification is required for this item
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jul 13, 2017
- Abate by
- Aug 8, 2017
- Penalty
- Initial $3,232 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) South east wall of the production floor: On and before February 13, 2017 employees using or working adjacent to the horizontal tumbler mixer were exposed to unguarded in-running nip points and rotating parts. Note: Abatement certification is required for this item.
Recent events (2)
- — I (S) $2000
- — Z (S) $3232
1910.219 C02 I
- Issued
- Jul 13, 2017
- Abate by
- Aug 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: (a) In the mix room: On and before February 13, 2017 employees using union process attritor mill were exposed to an unguarded rotating shaft. Note:Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 334513)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342102530.