Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CLAYTON METALS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CLAYTON METALS, INC. in 546 CLAYTON CT., WOOD DALE, IL 60191 (NAICS 423510). OSHA activity number 342111689.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Clayton Metals, INC. — free Get an email when a new federal OSHA severe-injury report for Clayton Metals, INC. is published. One employer, no account, unsubscribe in one click.
Site address
546 CLAYTON CT.
City
WOOD DALE
State
IL
ZIP
60191
Mailing
546 CLAYTON CT., WOOD DALE, IL 60191
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423510
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.147 C07 I A

Other-than-serious 1 instance 2 exposed
Issued
Jul 20, 2017
Abate by
Nov 3, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1910.147(c)(7)(i)(A):     Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolat(a) (LOCATION) (IDENTIFY SPECIFIC OPERATIONS AND/OR CONDITIONS) (IDENTIFY MACHINERY OR EQUIPMENT)
Recent events (2)
  • — I (O) $8873
  • — Z (S) $8873

1910.147 D03

Other-than-serious 1 instance 2 exposed
Issued
Jul 20, 2017
Abate by
Nov 3, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about February 8, 2017 the company did not ensure that the procedure for the Chicago Slitter was followed to render equipment safe from unexpected restart prior to employee(s) performing set-up and cleaning (servicing) in the following order:    1. Turn off and shut down the machines.     2. Physically locate and operate energy isolating devices in such a manner as to isolate the machines or equipment from the energy source(s).     3. Affix lockout or tagout devices to each energy isolating device.     4. Verify that isolation and de-energization of the machines or equipment have been accomplished.     Employees were exposed to unexpected start-up likely to result in amputation from in-going nip points on the slitter.  Circuit components/switches used in lieu of lockout/tagout did not provide effective alternative protection.       Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $8873
  • — Z (S) $8873

View Clayton Metals, INC.'s full OSHA safety record →