ARGYLE, NY —
OSHA Inspection: ADIRONDACK SCENIC, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ADIRONDACK SCENIC, INC. in 439 COUNTY ROUTE 45, ARGYLE, NY 12809 (NAICS 339999). OSHA activity number 342112976.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADIRONDACK SCENIC, INC.
- Site address
- 439 COUNTY ROUTE 45
- City
- ARGYLE
- State
- NY
- ZIP
- 12809
- Mailing
- 439 COUNTY ROUTE 45, ARGYLE, NY 12809
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339999
- Employees
- 169
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.134 G01 I A
- Issued
- May 24, 2017
- Abate by
- Jul 12, 2017
- Penalty
- Initial $11,408 · Current $7,986 Reduced
General-duty citation text
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function: (a) On or about 4/4/2017, in the fiberglass layup area were employees are required to wear a respirator, employees were observed by the CSHO having facial hair while wearing full and half-face respirators with management present.
Recent events (2)
- — I (O) $7985.6
- — Z (S) $11408
1910.134 I05 I
- Issued
- May 24, 2017
- Abate by
- Jul 12, 2017
- Penalty
- Initial $8,149 · Current $5,704 Reduced
General-duty citation text
29 CFR 1910.134(i)(5)(i): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated to prevent entry of contaminated air into the air-supply system: (a) On or about 2/17/17, in the spray booth where employees use supplied air, the employer did not ensure the air compressor was situated to prevent entry of contaminated air into the air supply system.
Recent events (2)
- — I (S) $5704.4
- — Z (S) $8149
1910.134 I01 II
- Issued
- May 24, 2017
- Abate by
- Jul 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(1)(ii): The employer did not ensure that compressed air used for respiration accords with the following specifications: Compressed breathing air shall meet at least the requirements for Grade D breathing air as described in ANSI/ Compressed Gas Association Commodity Specification for Air, G-7.1-1989. a) On or about 2/17/17, in the spray booth where employees are spraying Pitthane 35 Curing Agent B containing greater than 90% hexamethylene diisocyanate oligomers requires the use of atmosphere supplying respirator when sprayed. The employer did not ensure the compressed air is of Grade D.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.159 C10
- Issued
- May 24, 2017
- Abate by
- Jul 12, 2017
- Penalty
- Initial $8,149 · Current $5,704 Reduced
General-duty citation text
29 CFR 1910.159(c)(10): The minimum vertical clearance of 18 inches between automatic sprinkler systems sprinklers and the material below was not maintained: (a) On or about 2/17/2017, in the paint room, items were stacked up to the ceiling on shelving units well with in the 18 inch vertical clearance from automatic sprinkler heads.
Recent events (2)
- — I (S) $5704.4
- — Z (S) $8149
1910.176 B
- Issued
- May 24, 2017
- Abate by
- Jul 12, 2017
- Penalty
- Initial $6,519 · Current $0 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: (a) On or about 2/17/2017, in the paint room, items on shelves were not stacked so they could prevent accidental slipping and falling on to employees.
Recent events (2)
- — I (S) $0
- — Z (S) $6519
1910.305 G02 III
- Issued
- May 24, 2017
- Abate by
- Jul 12, 2017
- Penalty
- Initial $11,408 · Current $7,986 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) On or about 2/17/2017, in the wood shop were multi-density fiberboard is cut with power saws, flexible cords were not provided strain relief. (b) On or about 4/4/2017, in the fiberglass layup area, a flexible cord was observed not providing strain relief.
Recent events (2)
- — I (S) $7985.6
- — Z (S) $11408
More inspections at Adirondack Scenic, INC.