Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G&K SERVICES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of G&K SERVICES, INC. in 800 ISBELL ST., GREEN BAY, WI 54303 (NAICS 812332). OSHA activity number 342116126.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G&K Services, INC. — free Get an email when a new federal OSHA severe-injury report for G&K Services, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
G&K SERVICES, INC.
Site address
800 ISBELL ST.
City
GREEN BAY
State
WI
ZIP
54303
Mailing
800 ISBELL ST., GREEN BAY, WI 54303
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
812332
Employees
80
Ownership type
A

2 citations on file for this inspection.

1910.147 C05 II C 1

Other-than-serious 1 instance 1 exposed
Issued
Mar 29, 2017
Penalty
Initial $7,243 · Current $2,000 Reduced
29 CFR 1910.147(c)(5)(ii)(C)(1): Lockout devices. Lockout devices shall be substantial enough to prevent removal without the use of excessive force or unusual techniques, such as with the use of bolt cutters or other metal cutting tools.    (a)  On or about the week of February 13, 2017, employee(s) performing cleaning activities on the Jensen Jenform Omega Pro Steam Tunnel were utilizing American Lock (WNE j 3 Series A1100) which was not substantial in that the lock could be opened from the locked position without the use of the key.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $7243

1910.147 C06 II

Other-than-serious 1 instance 4 exposed
Issued
Mar 29, 2017
Abate by
May 17, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.  (a)  The employer's work order used to certify the periodic inspection had been performed did not contain all of the required elements.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View G&K Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342116126.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.