OSHA Inspection: OTIS ELEVATOR COMPANY

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of OTIS ELEVATOR COMPANY in 1300 MICCOSUKEE ROAD, TALLAHASSEE, FL 32308 (NAICS 333921). OSHA activity number 342116548.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Otis Elevator Company — free Get an email when a new federal OSHA severe-injury report for Otis Elevator Company is published. One employer, no account, unsubscribe in one click.
Site address
1300 MICCOSUKEE ROAD
City
TALLAHASSEE
State
FL
ZIP
32308
Mailing
4801 EXECUTIVE PARK CT. N. SUITE 208, JACKSONVILLE, FL 32216
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333921
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.146 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 9, 2017
Abate by
Sep 5, 2017
Penalty
Initial $12,675 · Current $12,675
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:  a. At the Tallahassee Memorial Healthcare hospital, Tallahassee, FL, Ground floor, Elevator Car #17, on or about February 17, 2017: the employers written confined space program did not require that this elevator pit be evaluated to determine whether it was a permit required confined space.
Recent events (3)
  • — F (S) $12675
  • — C (S) $12675
  • — Z (S) $12675

1910.146 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 9, 2017
Abate by
Sep 5, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations, including but not limited to; specifying acceptable entry conditions, isolating the permit space, and verifying that conditions in the permit space are acceptable for entry throughout the duration of an authorized entry:  a. At the Tallahassee Memorial Healthcare hospital, Tallahassee, FL, Ground floor, Elevator Car #17, on or about February 17, 2017: The employer's written confined space program did not specify acceptable entry conditions for this elevator pit.   b. At the Tallahassee Memorial Healthcare hospital, Tallahassee, FL, Ground floor, Elevator Car #17, on or about February 17, 2017: The employers written confined space program did not specify procedures to ensure isolation of the elevator pit.  c. At the Tallahassee Memorial Healthcare hospital, Tallahassee, FL, Ground floor, Elevator Car #17, on or about February 17, 2017: The employers written confined space program did not specify procedures to ensure that the conditions in the elevator pit were acceptable for entry throughout the duration of an authorized entry.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.146 G01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 9, 2017
Abate by
Sep 5, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146:    a. At the Tallahassee Memorial Healthcare hospital, Tallahassee, FL, Ground floor, Elevator Car #17, on or about February 17, 2017: the employer failed to train employees on the regulatory requirements of  29 CFR 1910.146 (permit required confined spaces) to acquire the understanding, knowledge, and skills necessary for the safe performance of their duties to other recognize and control serious safety hazards, such as but not limited to, struck-by and crushing hazards created by an energized and moving elevator within the hoist-way pit area.
Recent events (3)
  • — F (S) $0
  • — C (S) $12675
  • — Z (S) $12675

1910.147 C04 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Aug 9, 2017
Abate by
Sep 5, 2017
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a. The employer did not have a specific procedure developed, documented and utilized to control the hazardous energy of Elevator No. 17. On or about February 17, 2017, at the Tallahassee Memorial Healthcare hospital in Tallahassee, Florida, in the elevator hoist-way pit area of Elevator No. 17, an employee was exposed to struck-by and crushed-by hazards associated with an energized moving elevator car.
Recent events (3)
  • — F (S) $0
  • — C (S) $12675
  • — Z (S) $12675

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 9, 2017
Abate by
Sep 5, 2017
Penalty
Initial $0 · Current $12,675
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  a. At the Tallahassee Memorial Healthcare hospital, Tallahassee, FL, Ground floor, Elevator Car #17, on or about February 17, 2017: An employee was in an elevator pit area performing servicing and maintenance without having all of the elevator's hazardous energy sources locked and or tagged, which resulted in the employee being exposed to struck-by and crushed by hazards associated with an energized and moving elevator car.
Recent events (3)