JACKSON, MS —
OSHA Inspection: VINAMARK EXTERIOR DESIGN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VINAMARK EXTERIOR DESIGN in 1685 HIGH STREET, JACKSON, MS 39202 (NAICS 238130). OSHA activity number 342116795.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VINAMARK EXTERIOR DESIGN
- Site address
- 1685 HIGH STREET
- City
- JACKSON
- State
- MS
- ZIP
- 39202
- Mailing
- 4209 LAKELAND DRIVE #341, FLOWOOD, MS 39232
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.453 B02 V
- Issued
- Apr 28, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $3,422 · Current $2,053 Reduced
General-duty citation text
29 CFR 1926.453(b)(2)(v): A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift. Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e). (a) Right of the building - On or about February 17, 2017 two employees were exposed a fall hazard while riding in a Genie Lift S-40 serial no. JR5139 that was elevated 22 feet 6 inches above asphalt without fall protection. Also this aerial lifts occupancy capacity was exceeded. This aerial lift has maximum occupancy of 2 passengers. There were 3 employees inside the aerial lift.
Recent events (2)
- — I (S) $2053.2
- — Z (S) $3422
1926.453 B02 VI
- Issued
- Apr 28, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.453(b)(2)(vi): Boom and basket load limits specified by the manufacturer shall not be exceeded. (a) Right of the building - On or about February 17, 2017 three employees were exposed a fall hazard while riding in a Genie Lift S-40 serial no. JR5139 due to an exceeded occupancy capacity. This aerial lift has a warning sticker on the front that reads Maximum of 2 Occupants or 500 lbs.