Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MEMORIAL HERMANN HEALTH SYSTEM

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of MEMORIAL HERMANN HEALTH SYSTEM in 925 GESSNER SUITE 2564, HOUSTON, TX 77024 (NAICS 622110). OSHA activity number 342117611.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Memorial Hermann Health System — free Get an email when a new federal OSHA severe-injury report for Memorial Hermann Health System is published. One employer, no account, unsubscribe in one click.
Site address
925 GESSNER SUITE 2564
City
HOUSTON
State
TX
ZIP
77024
Mailing
929 GESSNER SUITE #2585, HOUSTON, TX 77024
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
622110
Employees
1829
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
Aug 4, 2017
Abate by
Aug 30, 2017
Penalty
Initial $12,675 · Current $7,605 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees were exposed to being caught-between a sliding door and a wall.  On or about February 9, 2017, in suite number 148 of the Linac Room, the sensor of the overhead BEA Iris Pedestrian Presence Detector was partially blocked,  while simultaneously the touch sensors on the NB-4000 Linac Slider Door failed to signal to retract upon contact with an object, which allowed the NB-4000 Linac Slider Door, serial number i10-4-306-1m, to close without retracting, creating a caught-between hazard.    Among other methods, feasible and acceptable abatement methods to correct this hazard include the following:    1.  Ensure that the sensor of the overhead BEA Iris Presence Detector is not blocked.  2.  Ensure that the door is operating within the parameters specified in Chapter 10.1 of ANSI/BHMA A156.10-2011, Standard for Power Operated Pedestrian Doors, to protect users from Entrapment (caught-between) hazards in sliding doors.  3.  Implement procedures, as recommended by the manufacturer in the owner's manual, for monthly inspections of the safety features.  4.  Implement procedures, as recommended by the manufacturer in their training video, for daily inspections of the door and sensors.