Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CROFT, LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CROFT, LLC in 1800 NORTH CLARK AVENUE, MAGNOLIA, MS 39652 (NAICS 332321). OSHA activity number 342124138.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Croft, LLC — free Get an email when a new federal OSHA severe-injury report for Croft, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
CROFT, LLC
Site address
1800 NORTH CLARK AVENUE
City
MAGNOLIA
State
MS
ZIP
39652
Mailing
1800 NORTH CLARK AVENUE, MAGNOLIA, MS 39652
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332321
Employees
216
Ownership type
A

16 citations on file for this inspection.

1910.28 B03 I

Serious Gravity 10 2 instances 2 exposed
Issued
Aug 18, 2017
Penalty
Initial $12,675 · Current $8,004 Reduced
29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section:    (a) Truck Shop - On or about February 22, 2017 skylights were not guarded or covered on roof where employees were working without fall protection or restraint.
Recent events (2)
  • — I (S) $8004
  • — Z (S) $12675

1910.28 B06 I

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $5,975 · Current $3,200 Reduced
29 CFR 1910.28(b)(6)(i): The employer did not ensure each employee less than 4 feet (1.2 m) above dangerous equipment was protected from falling into or onto the dangerous equipment by a guardrail system or a travel restraint system when the equipment was not covered or guarded to eliminate the hazard:    (a) Paint Department, Washer - On or about March 2, 2017 walkway over tanks containing hazardous chemicals including hydrochloric acid was open on both sides.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $5975

1910.28 B13 II

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 18, 2017
Penalty
Initial $9,958 · Current $5,550 Reduced
29 CFR 1910.28(b)(13)(ii):  When work is performed at least 6 feet (1.6 m) but less than 15 feet (4.6 m) from the roof edge, the employer did not ensure each employee is protected from falling by using a guardrail system, safety net system, travel restraint system, or personal fall arrest system:  (Note:  The employer may use a designated area when performing work that is both infrequent and temporary.)    (a) Truck Shop - On or about February 22, 2017 employees who moved skylights from forklift to roof of truck shop did not have fall protection and did not work inside a designated area.
Recent events (2)
  • — I (S) $5550
  • — Z (S) $9958

1910.146 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $5,975 · Current $3,200 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    (a)  Paint Department - On or about March 2, 2017 the employer had not evaluated the workplace to determine if any spaces were permit-required confined  spaces.  Employees enter washer to retrieve fallen parts and to clean and service the washer and its tanks.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $5975

1910.212 A01

Serious Gravity 5 15 instances 10 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $9,958 · Current $5,550 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Department 114 - On or about March 2, 2017 foot pedals on jamb presses were not guarded to prevent accidental activation.    (b) Prime Window Department - On or about March 2, 2017 foot pedals for aluminum slider fabrication machines were not guarded to prevent accidental activation.     (c) Tool Room - On or about March 9, 2017 a mill and 3 lathes were not guarded.
Recent events (2)
  • — I (S) $5550
  • — Z (S) $9958

1910.212 A03 II

Serious Gravity 5 18 instances 10 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:  (a) Fabrication - On or about March 2, 2017 frame punch press guard had 4.5" by 14" opening on front side and was open on top.  (b) Department 114 - On or about March 2, 2017 shop made vent jamb presses guards did not prevent operator from reaching point of operation.  (c) Prime Window Department - On or about March 2, 2017 shop made slider presses guards did not prevent operator from reaching point of operation.  (d) Plant site - On or about March 2, 2017 some foot pedal guards were not positioned to prevent accidental activation of the pedal and some were design with a half moon opening cut on the top front of guard exposing the pedal to accidental contact.   (e) 1600 Fabrication - On or about March 2, 2017 point of operation on z-bar machine was not guarded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 1 3 instances 2 exposed
Issued
Aug 18, 2017
Abate by
Aug 28, 2017
Penalty
Initial $5,975 · Current $3,200 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    (a) Tool room - On or about March 3, 2017 tongue guards on two bench grinders were not adjusted to within 1/4 inch of the abrasive wheels.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $5975

1910.303 F02

Serious Gravity 1 11 instances 3 exposed
Issued
Aug 18, 2017
Penalty
Initial $5,079 · Current $2,900 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    (a) Paint Department - On or about March 2, 2017 circuit breakers in panel for spray room were not labeled.
Recent events (2)
  • — I (S) $2900
  • — Z (S) $5079

1910.305 A01 I

Serious Gravity 1 3 instances 5 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $5,975 · Current $3,200 Reduced
29 CFR 1910.305(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not connected to all boxes, fittings, and cabinets to provide effective electrical continuity:    (a) Extrusion - On or about March 2, 2017 electrical conduit containing two individual conductors was broken on the 2200 press presenting sharp edge.     (b) Extrusion - On or about March 2, 2017 electrical conduit containing two individual conductors was not joined in continuous length on the 2200 press.    (c) Extrusion - On or about March 2, 2017 cable armor with two conductors was not joined at fitting on the 2200 press.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $5975

1910.305 B01 II

Serious Gravity 1 2 instances 2 exposed
Issued
Aug 18, 2017
Abate by
Aug 28, 2017
Penalty
Initial $5,975 · Current $3,200 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a)  Picture Windows - On or about March 2, 2017 electrical box labeled cooling fan 41 had two knock outs open on top allowing aluminum sawdust to enter.
Recent events (2)
  • — I (S) $3200
  • — Z (S) $5975

1910.147 C05 II D

Other-than-serious 6 instances 6 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s):  (a)  Plant Site - On are about February 24, 2017 locks used to control hazardous energy did not indicate the identity of the employee(s) applying the lock(s).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 II

Other-than-serious 1 instance 5 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  (a) Plant site - On or about February 24, 2017 the employer had not certified that an annual inspection of the energy control procedure had been performed.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 I B

Other-than-serious 40 instances 40 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:  (a) Plant Site - On or about February 24, 2017 employees that are affected by the control of hazardous energy were not trained as required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.242 B

Other-than-serious 4 instances 4 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a)  Vinyl Windows - On or about March 2, 2017 employees used compressed air operating at 80 psi for cleaning.  (b)  Tool room - On or about March 2, 2017 employees used compressed air operating at 80 psi for cleaning.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 3 instances 3 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   (a) Extrusion - On or about March 2, 2017 three electrical junction boxes on 2200 press did not have covers in place.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 3 instances 3 exposed
Issued
Aug 18, 2017
Abate by
Sep 12, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) Plant site - On or about March 9, 2017 not all employees had received effective training on hazard communication.  Some employees were not aware as to what a safety data sheet is.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Croft, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342124138.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.