COLUMBUS, OH —
OSHA Inspection: ABLE PALLET MFG. & REPAIR INC.
Unprogrammed Other inspection · Health discipline
At a glance
On , OSHA opened an unprogrammed Other health inspection of ABLE PALLET MFG. & REPAIR INC. in 1271 HARMON AVE, COLUMBUS, OH 43223 (NAICS 321920). OSHA activity number 342126752.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABLE PALLET MFG. & REPAIR INC.
- Site address
- 1271 HARMON AVE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43223
- Mailing
- PO BOX 23083, COLUMBUS, OH 43223
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.95 C01
- Issued
- Mar 21, 2017
- Abate by
- Apr 26, 2017
- Penalty
- Initial $2,463 · Current $1,724 Reduced
81108111
General-duty citation text
29 CFR 1910.95(c)(1): The employer shall administer a continuing, effective hearing conservation program, as described in paragraphs (c) through (o) of this section, whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale (slow response) or, equivalently, a dose of fifty percent. For purposes of the hearing conservation program, employee noise exposures shall be computed in accordance with appendix A and Table G-16a, and without regard to any attenuation provided by the use of personal protective equipment. a. At the work site, the employer had not established and implemented an effective hearing conservation program for employees with noise exposures equal to or exceeding an 8-hour time-weighted sound level (TWA) of 90 decibels measured on the A scale (slow response) or, equivalently, a dose of 50 per cent. An employee operating the pneumatic nail gun was exposed to noise at 111.6 % which exceeded the PEL (Permissible Exposure Limit) of 100%, an 8-hour time-weighted average sound level of 90 dBA. The employee's 8-hour TWA sound level was approximately 90.8 dBA during the 460 minute sampling period on March 1, 2017. Exposure calculation included a zero increment of the 20 minutes not sampled. b. At the work site, the employer had not established and implemented an effective hearing conservation program for employees with noise exposures equal to or exceeding an 8-hour time-weighted sound level (TWA) of 90 decibels measured on the A scale (slow response) or, equivalently, a dose of 50 per cent. An employee operating the pneumatic nail gun(builder) was exposed to noise at 339.0 % which exceeded the PEL (Permissible Exposure Limit) of 100%, an 8-hour time-weighted average sound level of 90 dBA. The employee's 8-hour TWA sound level was approximately 98.8 dBA during the 476 minute sampling period on March 1, 2017. Exposure calculation included a zero increment of the 4 minutes not sampled. c. At the work site, the employer had not established and implemented an effective hearing conservation program for employees with noise exposures equal to or exceeding an 8-hour time-weighted sound level (TWA) of 90 decibels measured on the A scale (slow response) or, equivalently, a dose of 50 per cent. An employee operating the pallet cutter was exposed to noise at 123.1 % which exceeded the PEL (Permissible Exposure Limit) of 100%, an 8-hour time-weighted average sound level of 90 dBA. The employee's 8-hour TWA sound level was approximately 91.5 dBA during the 465 minute sampling period on March 1, 2017. Exposure calculation included a zero increment of the 15 minutes not sampled.
Recent events (2)
- — I (S) $1724.1
- — Z (S) $2463
1910.1200 E01
- Issued
- Mar 21, 2017
- Abate by
- Apr 26, 2017
- Penalty
- Initial $1,847 · Current $1,293 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, material safety data sheets, and employee information and training will be met, and which also includes the following: a. At the work site, employees received, disassembled and repaired wooden pallets for re-sale. Pallets were moved from receiving to various areas and to storage using a propane-powered fork lift truck. The employer did not have a written hazard communication program for hazardous materials in use at the work site that included (but were not limited to) propane.
Recent events (2)
- — I (S) $1292.9
- — Z (S) $1847
More inspections at Able Pallet MFG. & Repair INC.
View Able Pallet MFG. & Repair INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342126752.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.