Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MORGAN ONE STEEL, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of MORGAN ONE STEEL, INC. in 7718 113TH ST., SEMINOLE, FL 33772 (NAICS 238120). OSHA activity number 342129731.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morgan ONE Steel, INC. — free Get an email when a new federal OSHA severe-injury report for Morgan ONE Steel, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7718 113TH ST.
City
SEMINOLE
State
FL
ZIP
33772
Mailing
13251 IDYLWILD FARM ROAD, FORT MYERS, FL 33905
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.760 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Apr 12, 2017
Penalty
Initial $5,577 · Current $3,346 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  a. On the west side roof of the building, three Morgan One Steel employees placing angle iron on the leading edge of the roof were not provided fall protection, exposing employees to a fall hazard of 32 feet 9 and 3/4 inches, on or about 2/23/2017.
Recent events (2)
  • — I (S) $3346.2
  • — Z (S) $5577

1926.453 B02 V

Repeat Gravity 5 1 instance 1 exposed
Issued
Apr 12, 2017
Penalty
Initial $7,968 · Current $4,781 Reduced
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift.  a. At the front of the building, the use of personal fall protection was not enforced while operating a JLG aerial lift, exposing the worker to a 32 feet 9 3/4 inch fall hazard, on or about 2/23/2017.  Morgan One Steel, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent  standard, which is contained in OSHA inspection 957340 citation number 1, item 1b and was affirmed as a final order on 3/13/2014. with respect to the workplace located at 3312 Lithia Pincrest Rd. Valrico, FL 33596.        .
Recent events (2)
  • — I (R) $4780.8
  • — Z (R) $7968

View Morgan ONE Steel, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342129731.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.