JOHNSTOWN, PA —
OSHA Inspection: FRIENDLY CITY BOX CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRIENDLY CITY BOX CO., INC. in 520 OAKRIDGE DRIVE, JOHNSTOWN, PA 15904 (NAICS 322212). OSHA activity number 342130077.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRIENDLY CITY BOX CO., INC.
- Site address
- 520 OAKRIDGE DRIVE
- City
- JOHNSTOWN
- State
- PA
- ZIP
- 15904
- Mailing
- 520 OAKRIDGE DRIVE, JOHNSTOWN, PA 15904
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 322212
- Employees
- 11
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Apr 19, 2017
- Penalty
- Initial $4,346 · Current $2,962 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Jobsite, 520 Oakridge Drive, Johnstown, PA 15904: On or about February 24, 2017, during box manufacturing operations on the left hand box cutting machine and the gluer machine, the employer did not ensure that the machines were turned off and the energy source isolated, therefore exposing employees to amputation type injuries while employees were resetting these machines due to a temporary loss of power.
Recent events (2)
- — I (S) $2962
- — Z (S) $4346
1910.212 A01
- Issued
- Apr 19, 2017
- Penalty
- Initial $3,622 · Current $2,238 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazards created by: a) Jobsite, 520 Oakridge Drive, Johnstown, PA 15904: On or about February 24, 2017, during box manufacturing operations on the left hand box cutting machine, near the operators control panel (center of machine-facing west), the employer did not ensure that the machine was guarded from rotating shaft/gears exposing employees to caught in/caught in-between hazards. b) Jobsite, 520 Oakridge Drive, Johnstown, PA 15904: On or about February 24, 2017, during box manufacturing operations on the left hand box cutting machine (center of machine, facing east), the employer did not ensure that the machine was guarded from rotating gears/belts exposing employees to caught in/caught in-between hazards.
Recent events (2)
- — I (S) $2238
- — Z (S) $3622
1910.303 G01 II
- Issued
- Apr 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space around electric equipment rated 600 volts, nominal, or less to ground, was used for storage: (a) Jobsite, 520 Oakridge Drive, Johnstown PA 15904: On or about February 26, 2017, during box manufacturing activities, electrical equipment/panels were obstructed near the left hand box cutting machine on the main production floor.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Apr 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Jobsite, 520 Oakridge Drive, Johnstown PA 15904: On or about February 24, 2017, during production operations near the bathroom area, the employer did not ensure that permanent wiring was in use, that a flexible cable was run from the ceiling and down to power the coffee pot and water cooler.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 322212)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342130077.