Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATHA INTERIOR TRIM, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ATHA INTERIOR TRIM, INC. in 100 PETTY RD., SUITE C, LAWRENCEVILLE, GA 30043 (NAICS 321911). OSHA activity number 342131117.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atha Interior Trim, INC. — free Get an email when a new federal OSHA severe-injury report for Atha Interior Trim, INC. is published. One employer, no account, unsubscribe in one click.
Site address
100 PETTY RD., SUITE C
City
LAWRENCEVILLE
State
GA
ZIP
30043
Mailing
75 PARKWAY DRIVE NORTH, ZEBULON, GA 30295
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321911
Employees
12
Ownership type
A

20 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 16, 2017
Penalty
Initial $5,387 · Current $5,068 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to explosion hazards and sharp particles flying in the air when PVC pipe was used as a compressed air line to provide compressed air to staple guns.  On or about February 22, 2017, employees were exposed to explosion and sharp flying particles in the air when PVC pipe was used to provide compressed air for the staple guns at the door tables.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $5068
  • — Z (S) $5387

5(a)(1)

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $5,070 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): : The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees, in that employees were exposed to struck-by hazards.   On or about February 22, 2017, employees were exposed to struck-by hazards when the platform for the compressor's air dryer was cracked and bowed.  The platform was a pallet that had been mounted on legs that only supported the outer edges of the pallet.  Employees walk in the area every day.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $5070

1910.22 D01

Serious Gravity 5 3 instances 3 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $5,070 · Current $5,070
29 CFR 1910.22(d)(1): Walking-working surfaces are were not inspected, regularly, and maintained in a safe condition.  On or about February 22, 2017, employees walking and working in the area were exposed to trip hazards due to the following: a. an extension cord had been routed across the floor to a fan at a door table  b. PVC pipe was routed across the floor to the door tables and the router bench c. metal pipe was routed across the floor from the wall to the router bench (electrical conduit)  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $5070
  • — Z (S) $5070

1910.28 B01 I

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $3,802 · Current $0 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:  On or about February 22, 2017, employees were exposed to fall hazards when there were no guardrails and the height of the top of the ramp at the back of the building was 53".  Employees used the ramp to access the dumpster and to load/unload trucks.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $3802

1910.37 B02

Deleted Serious Gravity 1 1 instance 3 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  On or about February 22, 2017, employees were exposed to fire hazards when the exit door on the left when walking toward the back of the building did not have an exit sign.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B04

Deleted Serious Gravity 1 2 instances 3 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  On or about February 22, 2017, employees were exposed to fire hazards when the exits could not be seen because of the materials in the warehouse and there were no directional exit signs to indicate the location of the exits.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 16, 2017
Penalty
Initial $5,070 · Current $5,070
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment:  On or about February 22, 2017, employees were exposed to struck-by and contact hazards when the work site had not been evaluated to determine when personal protective equipment such as, but not limited to, safety glasses, hard hats, and gloves should be used.  Employees handle wood and doors.  Employees use equipment such as, but not limited to, staplers, routers, and saws.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $5070
  • — Z (S) $5070

1910.133 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): Protective eye and face equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:  On or about February 22, 2017, employees were exposed to eye hazards when safety glasses were not required when employees were using routers and staple guns to manufacture pre-hung interior doors.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Deleted Serious Gravity 1 3 instances 4 exposed
Issued
Jun 16, 2017
Penalty
Initial $3,802 · Current $0 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  On or about February 22, 2017, employees were exposed to fire hazards when fire extinguishers where employees walk and work were blocked by materials: a. The fire extinguisher next the right exit on the back wall was not accessible due to material blocking access to the area b. The fire extinguisher next to the left exit on the back wall had a fan in front of it. c. The fire extinguisher next to the door from the office had a container in front of it.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3802

1910.178 L01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $3,802 · Current $3,802
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck:  On or about February 22, 2017, employees were exposed to struck-by hazards when the employer had not evaluated the competency of drivers with previous training experience nor provided training for them.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $3802
  • — Z (S) $3802

1910.178 P01

Serious Gravity 1 1 instance 2 exposed
Issued
Jun 16, 2017
Penalty
Initial $3,802 · Current $1,901 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  On or about February 22, 2017, employees were exposed to fall hazards when the Caterpillar forklift with the loose seat cushion had not been taken out of service.  No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $1901
  • — Z (S) $3802

1910.178 Q07

Serious Gravity 1 1 instance 3 exposed
Issued
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  On or about February 22, 2017, employees were exposed to struck-by hazards when the forklifts in use at the site were not inspected on a daily basis.   No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $6,338 · Current $6,338
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  On or about February 22, 2017, employees were exposed to struck-by hazards when the staple guns had been set up to permit operation without the muzzle in contact with the work surface.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $6338
  • — Z (S) $6338

1910.22 A01

Deleted Other-than-serious 1 instance 3 exposed
Issued
Jun 16, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(1): The employer failed to provide a clean and sanitary condition for all places of employment, passageways, storerooms, service rooms, and walking-working surfaces.  On or about February 22, 2017, employees were exposed to fire hazards when dust was permitted to accumulate in thicknesses greater than 1/4 inch on a pipe on the wall located above the electrical panels.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 4 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  On or about February 22, 2017, the employer did not have a written hazard communication program.  Employees use propane to power the forklifts at the site.  Employees maintain the delivery trucks by adding fluids such as, but not limited to power steering fluid. Employees working at the routers and saw generate wood dust.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 G01

Other-than-serious 1 instance 4 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:  On or about February 22, 2017, there were no Safety Data Sheets (SDS) for any of the chemicals in use at the site.  Employees use propane to power the forklifts.  Employees maintain the delivery trucks by adding fluids such as, but not limited to, power steering fluid.  Employees working at the routers and saw generate wood dust.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 4 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about February 22, 2017, employees had not been provided training or information on the chemicals in use at the site.  Employees use propane to power the forklifts.  Employees maintain the delivery trucks by adding fluids such as, but not limited to, power steering fluid.  Employees working at the routers and saw generate wood dust.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 A03

Other-than-serious 2 instances 3 exposed
Issued
Jun 16, 2017
Penalty
Initial $3,802 · Current $0 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    On or about February 22, 2017, employees were exposed to fire hazards when the exits in the warehouse/production area were blocked by materials.  a. exit on the right at the back of the building could not be accessed without climbing over materials  b. exit on the left at the back of the building had a bander and boxes in the path to the exit    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $3802

1910.37 B06

Other-than-serious 1 instance 3 exposed
Issued
Jun 16, 2017
Abate by
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:    On or about February 22, 2017, employees were exposed to fire hazards when the exit sign over the door to the office area was broken.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.303 G01 II

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Jun 16, 2017
Penalty
Initial $5,070 · Current $0 Reduced
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    On or about February 22, 2017, the space between the front of the electrical equipment panels and the yellow posts used to denote the required clear space was full of and overflowing with empty cardboard boxes.  The boxes made it difficult to access the electrical equipment panels.  The boxes also posed a fire hazard if there were an electric arc.  Employees work next to the area to store/retrieve small parts in the bins/racks next to the yellow posts.    No abatement certification or documentation is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (S) $5070

View Atha Interior Trim, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342131117.