HIALEAH GARDENS, FL —
OSHA Inspection: DAB DOOR COMPANY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAB DOOR COMPANY, INC. in 12195 NW 98 AVE., HIALEAH GARDENS, FL 33018 (NAICS 332321). OSHA activity number 342132651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAB DOOR COMPANY, INC.
- Site address
- 12195 NW 98 AVE.
- City
- HIALEAH GARDENS
- State
- FL
- ZIP
- 33018
- Mailing
- 12195 NW 98 AVE., HIALEAH GARDENS, FL 33018
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332321
- Employees
- 15
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 15, 2017
- Abate by
- Jul 12, 2017
- Penalty
- Initial $2,897 · Current $1,738 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about 2/23/2017, at the above addressed work site, employees were exposed to ingoing nip points and rotating parts hazard due to lack of machine guarding on the uncoiler machine located in the west end area of the warehouse. PLEASE NOTE: CERTIFICATION OF ABATEMENT IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (S) $1738.2
- — Z (S) $2897
1910.212 B
- Issued
- Jun 15, 2017
- Penalty
- Initial $2,463 · Current $1,478 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine designed for fixed location was not securely anchored to prevent walking or moving: On or about 2/23/2017, at the above addressed work site, the employer did not ensure the punch press located at the west section of the warehouse was securely anchored onto the floor.
Recent events (2)
- — I (S) $1477.8
- — Z (S) $2463
1910.219 B01
- Issued
- Jun 15, 2017
- Penalty
- Initial $2,463 · Current $1,478 Reduced
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel with parts seven feet or less above floor was not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a): On or about 2/23/2017, at the above addressed work site, an employee operating the punch press was exposed to caught-in-between hazards due to lack of a guard on the flywheel.
Recent events (2)
- — I (S) $1477.8
- — Z (S) $2463
1904.32 A04
- Issued
- Jun 15, 2017
- Penalty
- Initial $724 · Current $434 Reduced
General-duty citation text
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30: On or about 2/23/2017, at the above addressed jobsite, the employer failed to post the annual summary of work-related injuries and illness, which an employee suffered a minor injury that resulted in job restriction.
Recent events (2)
- — I (O) $434.4
- — Z (O) $724
1910.37 A03
- Issued
- Jun 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: On or about 2/23/2017, at the above addressed work site, the employer did not ensure the exit routes were kept free and unobstructed, which material was stored in front of the emergency exit door.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B05
- Issued
- Jun 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): On or about 2/23/2017, at the above addressed work site, the employer did not ensure a bathroom door adjacent to another door that was leading to an exit route was marked "Not and Exit" or be identified by a sign indicating it was a bathroom.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.176 B
- Issued
- Jun 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: On or about 2/23/2017, at the above addressed work site, the employer did not ensure ladders that were stored were secured to prevent sliding and collapse.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.178 Q01
- Issued
- Jun 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and/or repairs were not made by authorized personnel: On or about 2/23/2017, at the above addressed work site, the employer did not ensure the YALE forklift was taken out of service due to a defective horn.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 D01
- Issued
- Jun 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(d)(1): Switchboards with exposed live parts were not located in permanently dry locations and were not made accessible only to qualified persons: On or about 2/23/2017, at the above addressed work site, the employer did not ensure the electrical panel was accessible to qualified persons due to equipment and furniture being stored in front of the electrical panel.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.334 A02 II
- Issued
- Jun 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: On or about 2/23/2017, at the above addressed work site, the employer did not ensure the strain relief attached to a permanent foot pedal did not have any exposed wires.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at DAB Door Company, INC.
View DAB Door Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332321)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342132651.