Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STILES CONTRACTING OF CENTRAL NEW YORK, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STILES CONTRACTING OF CENTRAL NEW YORK, LLC. in CORTLANDVILLE FIRE DEPARTMENT, 951 NY ROUTE 13, CORTLAND, NY 13045 (NAICS 236118). OSHA activity number 342133824.

Watch Stiles Contracting OF Central NEW York, LLC. — free Get an email when a new federal OSHA severe-injury report for Stiles Contracting OF Central NEW York, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
CORTLANDVILLE FIRE DEPARTMENT, 951 NY ROUTE 13
City
CORTLAND
State
NY
ZIP
13045
Mailing
1336 ROUTE 392, CORTLAND, NY 13045
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1141.00 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:    a) Northeast corner of building, on or about 2-22-17:  Two employees were operating a compressor, powered through a receptacle that was not protected by a ground fault circuit interrupter (GFCI).     b) Southeast corner of building, on or about 2-22-17:  Two employees were operating a circular saw, powered through a receptacle that was not protected by a ground fault circuit interrupter (GFCI).     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1141
  • — Z (S) $1630

1926.404 F06

Serious Gravity 1 3 instances 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) Northeast corner of building, on or about 2-22-17:  Two employees were operating a compressor, powered through an extension cord that did not have a continuous path to ground due to a missing ground pin.     b) Northeast corner of building, on or about 2-22-17:  Two employees were operating a compressor with a power cord that did not have a continuous path to ground due to a missing ground pin.     c) Southeast corner of building, on or about 2-22-17:  Two employees were operating a circular saw, powered through an extension cord that did not have a continuous path to ground due to a missing ground pin.     ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1901.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a) South side of roof, on or about 2-22-17:  Two employees were performing roofing work on a sloped roof (10:12 pitch) and were not protected from falls, exposing the employees to a fall hazard of 11 feet 11 inches.      ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
  • — I (S) $1901.2
  • — Z (S) $2716

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342133824.