NEWTOWN SQUARE, PA —
OSHA Inspection: DAVIS VISION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of DAVIS VISION in 3805 WEST CHESTER PIKE, SUITE 150, BLDG D, NEWTOWN SQUARE, PA 19073 (NAICS 446130). OSHA activity number 342134889.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAVIS VISION
- Site address
- 3805 WEST CHESTER PIKE, SUITE 150, BLDG D
- City
- NEWTOWN SQUARE
- State
- PA
- ZIP
- 19073
- Mailing
- 3805 WEST CHESTER PIKE, SUITE 150, BLDG D, NEWTOWN SQUARE, PA 19073
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 446130
- Employees
- 300
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.305 B01 II
- Issued
- Apr 6, 2017
- Penalty
- Initial $4,617 · Current $3,694 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Finishing Area: On or about 01/18/2016, a junction box on the southeast wall has an unused opening that was not closed, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $3693.6
- — Z (S) $4617
1910.305 J02 IV
- Issued
- Apr 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(iv): A receptacle installed in a wet or damp location was not suitable for the location: (a) Alloy Reclaim Area: On or about 11/2/2016, a receptacle next to the water bath was not rated for wet location, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $12,675 · Current $7,243 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: (a) ARC Coating: On or about 1/11/2017, Employees were performing voltage testing and other work on energized electrical conductors and circuit parts, without the use of rubber insulating gloves, exposing employees to electrical hazards. (b) Finishing room: On or about 1/18/2017, Employees were performing voltage testing on energized electrical conductors and circuit parts, without the use of rubber insulating gloves, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $7243.2
- — Z (S) $12675
1910.335 A01 V
- Issued
- Apr 6, 2017
- Abate by
- May 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes or face: (a) ARC Coating: On or about 1/11/2017, Employees were performing voltage testing and other work on energized electrical conductors and circuit parts, without the use of an arc-rated faceshield, exposing employees to electrical explosion hazards. (b) Finishing room: On or about 1/18/2017, Employees were performing voltage testing on energized electrical conductors and circuit parts, without the use of an arc-rated faceshield, exposing employees to electrical explosion hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Davis Vision
View Davis Vision's full OSHA safety record →
More inspections in this industry (NAICS 446130)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342134889.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.