Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: DEEP EAST TEXAS ELECTRIC COOPERATIVE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of DEEP EAST TEXAS ELECTRIC COOPERATIVE, INC. in HIGHWAY 81 WEST AND CR 3801 POLE 157512, JOAQUIN, TX 75954 (NAICS 221121). OSHA activity number 342136017.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Deep East Texas Electric Cooperative, INC. for free Get an email when a new federal OSHA severe-injury report for Deep East Texas Electric Cooperative, INC. is published. One employer, no account, unsubscribe in one click.
Site address
HIGHWAY 81 WEST AND CR 3801 POLE 157512
City
JOAQUIN
State
TX
ZIP
75954
Mailing
P.O. BOX 736, SAN AUGUSTINE, TX 75972
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221121
Employees
125
Ownership type
Private (A)

1 citation on file for this inspection.

1910.269 N02

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 9, 2017
Abate by
Jul 12, 2017
Penalty
Initial $11,408 · Current $7,985 Reduced
29 CFR 1910.269(n)(2): For any employee to work transmission and distribution lines or equipment as deenergized, the employer did not ensure that the lines or equipment were deenergized under the provisions of paragraph (m) of this section and did not ensure proper grounding of the lines or equipment as specified in paragraphs (n)(3) through (n)(8) of this section:    a)  This violation occurred on or about February 23, 2017, when employees working on ungrounded power lines were exposed to electrical hazards.
Recent events (2)
  • · I (S) $7985
  • · Z (S) $11408

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342136017.