Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MASTERS BUILDERS INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of MASTERS BUILDERS INC in 28 GOLFVIEW DR., MEDFORD, NJ 08055 (NAICS 238130). OSHA activity number 342142015.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Masters Builders INC — free Get an email when a new federal OSHA severe-injury report for Masters Builders INC is published. One employer, no account, unsubscribe in one click.
Site address
28 GOLFVIEW DR.
City
MEDFORD
State
NJ
ZIP
08055
Mailing
272 DUNNS MILL RD. SUITE 262, BORDENTOWN, NJ 08505
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
26
Ownership type
A

13 citations on file for this inspection.

1926.100 A

Serious Gravity 10 6 instances 6 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,873 · Current $8,873
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a)  North side, entrance overhang: Three employees exposed to head injury while working on the entrance overhang without any head protection; using hammers and nail guns to attach framing lumber and standing under other employees working above them; on or about 02/24/2017;  b)  North side, entrance overhang: Employee without head protection was holding the 6' step ladder while another employee climbed the ladder with an approximate 29 foot long 2x10 inch plank on his shoulder, employee climbing ladder not using any head protection, on or about 02/24/2017;   c)  North side, west end of building; exterior wall of the Pro-Shop:  Employee without head protection and working from an improperly set up extension ladder was using a pneumatic nail gun while attaching sheeting above the windows, on or about 02/24/2017.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8873

1926.102 A01

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a)  North side of entrance overhang on roof:  Employee using a pneumatic nail gun while installing framing pieces for the eaves of the entrance overhang was not using any eye protection, on or about 02/24/2017;   b)  North side, west end of building; exterior wall of the Pro-Shop:  Employee using a pneumatic nail gun while attaching sheeting above the windows was not using any eye protection, on or about 02/24/2017.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1926.451 A01

Serious Gravity 10 2 instances 3 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,874 · Current $8,874
29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it:   a)  North side of entrance overhang: Employees without any fall protection worked on the underside of the entrance overhang from the makeshift scaffold fabricated from left over lumber at heights between approximately 9 feet 10 inches and 11 feet, on or about 02/24/2017;   b)  North side of entrance overhang: Employee without any fall protection approximately 18-20 feet above ground level, without any type of fall protection, was standing on top of an unsecured sheet of OSB resting on the forks of the Model B-66 Pettibone Telehandler while removing construction debris from the roof of the overhang, on or about 02/254/2017.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8874

1926.451 C02 V

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,874 · Current $8,874
29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and the fork-lift was moved horizontally while the platform was occupied:  a)  North side of entrance overhang: Employee without any fall protection approximately 18-20 feet above ground level, without any type of fall protection, was standing on top of an unsecured sheet of OSB resting on the forks of the Model B-66 Pettibone Telehandler while removing construction debris from the roof of the overhang, boom was extended and retracted while employee stood on the platform, on or about 02/24/2017.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8874

1926.451 C03

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,874 · Current $8,874
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, posts, frames, and uprights were not plumb and braced to prevent swaying and displacement:  a)  North side of entrance overhang:  Employees without any fall protection were working at heights between approximately 9 feet 10 inches and 11 feet from a makeshift wooden scaffold fabricated from left over lumber; platform was supported by posts made from overlapping lengths of 2x4 inch and 2x4 inch nailed to 2x6 inch pieces of lumber without any cross bracing, on or about 02/24/2017.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8874

1926.451 G01

Serious Gravity 10 3 instances 4 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,874 · Current $8,874
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a)  North side of entrance overhang: Employee without fall protection working approximately 18-20 feet without any fall protection was working from an inadequate wood scaffold, fabricated from leftover scrap lumber, on or about 02/24/2017;  b)  North side of entrance overhang: Employee without any fall protection approximately 18-20 feet above ground level, without any type of fall protection, was standing on top of an unsecured sheet of OSB resting on the forks of the Model B-66 Pettibone Telehandler while removing construction debris from the roof of the overhang, on or about 02/24/2017.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8874

1926.501 B10

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.  Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system:  a) North side of entrance overhang: Employee without any fall protection work within 1-2 feet of the edge of the roof approximately 11 feet above ground level, on or about 02/24/2017.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1926.1051 A

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,874 · Current $8,874
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:  a)  North side of building, east side of where entrance overhang intersects with the roof: Employee without any type of fall protection hopped down from the edge of the approximately 11-12 foot high eves to the top surface of the makeshift wooden scaffold approximately 36 inches below, on or about 02/24/2017.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8874

1926.1053 B05 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support):  a)  North side, west end of building; exterior wall of the Pro-Shop:  Employee approximately 7-8 feet above ground level worked from the 24 ft Werner Aluminum extension ladder setup at approximated 52° to the horizontal, on or about 02/24/2017.  NOTE:  THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1926.1053 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,874 · Current $8,874
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a)  North side of entrance overhang; northeast corner of building: Employee was standing on top of the Werner 6 Fiberglass Step Ladder while placing an approximately 29 feet long plank on fabricated bearers of a makeshift scaffold, on or about, 02/2402017.   NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8874

1926.1053 B15

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use:  a)  North entrance overhang: Employee was using a ladder that resembles the Werner FS106 6 ft Type I Fiberglass Single Sided Step Ladder which didn't have labeling that could be read; employee was standing on top of ladder while supporting one end of 2x10x approximate 29 foot long wood plank, on or about 02/24/2017.       NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

1926.1053 B21

Serious Gravity 10 2 instances 2 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $8,874 · Current $8,874
29 CFR 1926.1053(b)(21): Each employee shall use at least one hand to grasp the ladder when progressing up and/or down the ladder.   a)  North side, west end of building; exterior wall of the Pro-Shop:  Employee with a pneumatic nail gun in one hand, walked up the 24 ft Werner Aluminum extension ladder to a position approximately 7-8 feet above ground level; ladder not extended and positioned at approximated 52° to the horizontal, on or about 02/24/2017;  b)  North side of entrance overhang; northeast corner of building: Employee, while holding one end of the makeshift 29 foot long 2x10 inch plank, climbed to and stood on the top of the 6 Fiberglass Step Ladder, on or about 02/24/2017.    NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $8874

1926.1053 B22

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 24, 2017
Abate by
Jul 28, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(22): Employees  using ladders were carrying objects or loads that could cause the employee to lose balance and fall:  a)  North side of entrance overhang; northeast corner of building: Employee, while holding one end of the makeshift 29 foot long 2x10 inch plank, climbed to and stood on the top of the 6 foot Fiberglass Step Ladder, on or about 02/24/2017.  NOTE:  IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
  • — Z (S) $0

View Masters Builders INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342142015.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.