HOUSTON, TX —
OSHA Inspection: DAYTON STEEL FABRICATORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DAYTON STEEL FABRICATORS in 7718 LETTIE ST, HOUSTON, TX 77075 (NAICS 332323). OSHA activity number 342146263.
Where did this inspection happen?
- Establishment
- DAYTON STEEL FABRICATORS
- Site address
- 7718 LETTIE ST
- City
- HOUSTON
- State
- TX
- ZIP
- 77075
- Mailing
- 7718 LETTIE ST, HOUSTON, TX 77075
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 12
- Ownership type
- A
Citations
12 citations on file for this inspection.
1910.179 J03
- Issued
- Abate by
- Penalty
- Initial $4346.00 · Current $1304.00 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: a) At the site, a complete inspection of a COFFING overhead crane that was in use had not taken place within the past 12 months, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $4346
1910.179 L03 II C
- Issued
- Abate by
- Penalty
- Initial $4346.00 · Current $1304.00 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(ii)(c): Control systems were not maintained to assure correct function of components: a) At the site, control systems for a COFFING overhead crane were not maintained to assure correct function, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $4346
1910.184 D
- Issued
- Abate by
- Penalty
- Initial $4346.00 · Current $1304.00 Reduced
General-duty citation text
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer: a) At the site, synthetic web slings were not inspected for damage by a competent person, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $4346
1910.184 I09 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service: a) At the site, a synthetic web sling with visible cuts and snags was used, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 C14
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(c)(14): Slings without affixed and legible identification markings were used: a) At the site, a synthetic web sling without legible identification markings was used to hoist steel tubing, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) At the site, alloy steel chain slings that were being used did not have permanently affixed and durable identification markings, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $1521.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) At the site, an FMB bandsaw was not provided with guarding at the point of operation, Model # Antares, SN# T00839, exposing employees to amputation hazards. b) At the site, an FMB bandsaw was not provided with guarding at the point of operation, Model # Antares, SN# U00836, exposing employees to amputation hazards.
Recent events (2)
- — I (S) $1521
- — Z (S) $5070
1910.243 C01 II A
- Issued
- Abate by
- Penalty
- Initial $4346.00 · Current $1304.00 Reduced
General-duty citation text
29 CFR 1910.243(c)(1)(ii)(a): Safety guard(s) for portable abrasive wheel(s) did not cover the spindle end, and flange projections: a) At the site, a DEWALT small angle grinder was used without a grinding wheel guard, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $4346
1910.252 B02 III
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) At the site, employees working adjacent to welding operations were not protected from welding rays, exposing employees to flash burns.
Recent events (2)
- — I (S) $1086.6
- — Z (S) $3622
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: a) At the site, oxygen cylinders in storage were not separated from fuel-gas cylinders by a minimum distance of 20 feet or an adequate fire barrier, exposing employees to fire hazards.
Recent events (2)
- — I (S) $1086.6
- — Z (S) $3622
1910.305 G02 III
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) At the site, an extension cord being used to power a DEWALT small angle grinder was not equipped with strain relief, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1086.6
- — Z (S) $3622
1910.334 A02 II
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) At the site, an extension cord with damage to its outer jacket was in use, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1086.6
- — Z (S) $3622
More inspections in this industry (NAICS 332323)
PACOIMA, CA—2026-07-14
AMERICAN IRONWORKS MANUFACTURING, INC.
MIDLOTHIAN, VA—2026-07-09
MORRIS INDUSTRIES, INC
PATERSON, NJ—2026-07-08
TOWN GATE CO. INC.
HUDSON, NC—2026-07-01
161479 - TRINITY MANUFACTURING GROUP, LLC
ARCHBOLD, OH—2026-06-30
BIL-JAX INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source