HOUSTON, TX ·
OSHA Inspection: DAYTON STEEL FABRICATORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DAYTON STEEL FABRICATORS in 7718 LETTIE ST, HOUSTON, TX 77075 (NAICS 332323). OSHA activity number 342146263.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAYTON STEEL FABRICATORS
- Site address
- 7718 LETTIE ST
- City
- HOUSTON
- State
- TX
- ZIP
- 77075
- Mailing
- 7718 LETTIE ST, HOUSTON, TX 77075
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 12
- Ownership type
- Private (A)
Citations
12 citations on file for this inspection.
1910.179 J03
- Issued
- Aug 10, 2017
- Abate by
- Apr 5, 2018
- Penalty
- Initial $4,346 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.179(j)(3): A complete periodic inspection of crane(s) had not been conducted in the past 12 months: a) At the site, a complete inspection of a COFFING overhead crane that was in use had not taken place within the past 12 months, exposing employees to struck by hazards.
Recent events (2)
- · I (S) $1303.8
- · Z (S) $4346
1910.179 L03 II C
- Issued
- Aug 10, 2017
- Abate by
- Apr 5, 2018
- Penalty
- Initial $4,346 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(ii)(c): Control systems were not maintained to assure correct function of components: a) At the site, control systems for a COFFING overhead crane were not maintained to assure correct function, exposing employees to struck by hazards.
Recent events (2)
- · I (S) $1303.8
- · Z (S) $4346
1910.184 D
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $4,346 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.184(d): Each day before being used, the sling and all fastenings and attachments were not being inspected for damage or defects by a competent person designated by the employer: a) At the site, synthetic web slings were not inspected for damage by a competent person, exposing employees to struck by hazards.
Recent events (2)
- · I (S) $1303.8
- · Z (S) $4346
1910.184 I09 III
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service: a) At the site, a synthetic web sling with visible cuts and snags was used, exposing employees to struck by hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.184 C14
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(c)(14): Slings without affixed and legible identification markings were used: a) At the site, a synthetic web sling without legible identification markings was used to hoist steel tubing, exposing employees to struck by hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.184 E01
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: a) At the site, alloy steel chain slings that were being used did not have permanently affixed and durable identification markings, exposing employees to struck by hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.212 A03 II
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $5,070 · Current $1,521 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) At the site, an FMB bandsaw was not provided with guarding at the point of operation, Model # Antares, SN# T00839, exposing employees to amputation hazards. b) At the site, an FMB bandsaw was not provided with guarding at the point of operation, Model # Antares, SN# U00836, exposing employees to amputation hazards.
Recent events (2)
- · I (S) $1521
- · Z (S) $5070
1910.243 C01 II A
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $4,346 · Current $1,304 Reduced
General-duty citation text
29 CFR 1910.243(c)(1)(ii)(a): Safety guard(s) for portable abrasive wheel(s) did not cover the spindle end, and flange projections: a) At the site, a DEWALT small angle grinder was used without a grinding wheel guard, exposing employees to struck by hazards.
Recent events (2)
- · I (S) $1303.8
- · Z (S) $4346
1910.252 B02 III
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $3,622 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: a) At the site, employees working adjacent to welding operations were not protected from welding rays, exposing employees to flash burns.
Recent events (2)
- · I (S) $1086.6
- · Z (S) $3622
1910.253 B04 III
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $3,622 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: a) At the site, oxygen cylinders in storage were not separated from fuel-gas cylinders by a minimum distance of 20 feet or an adequate fire barrier, exposing employees to fire hazards.
Recent events (2)
- · I (S) $1086.6
- · Z (S) $3622
1910.305 G02 III
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $3,622 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: a) At the site, an extension cord being used to power a DEWALT small angle grinder was not equipped with strain relief, exposing employees to electrical hazards.
Recent events (2)
- · I (S) $1086.6
- · Z (S) $3622
1910.334 A02 II
- Issued
- Aug 10, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $3,622 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) At the site, an extension cord with damage to its outer jacket was in use, exposing employees to electrical hazards.
Recent events (2)
- · I (S) $1086.6
- · Z (S) $3622
More inspections in this industry (NAICS 332323)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342146263.