LAKEWOOD, CO ·
OSHA Inspection: BRAMAN COLORADO EUROPEAN IMPORTS, INC.
Follow-up inspection · Health discipline
At a glance
On , OSHA opened a follow-up health inspection of BRAMAN COLORADO EUROPEAN IMPORTS, INC. in 1590 DOVER STREET, LAKEWOOD, CO 80215 (NAICS 811121). OSHA activity number 342149689.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRAMAN COLORADO EUROPEAN IMPORTS, INC.
- Site address
- 1590 DOVER STREET
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80215
- Mailing
- 1590 DOVER STREET, LAKEWOOD, CO 80215
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 19
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.134 E03 I
- Issued
- Mar 15, 2017
- Abate by
- Apr 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(3)(i): The employer did not provide a follow-up medical examination for employees who gave a positive response to any question among questions 1 through 8 in Section 2, Part A of Appendix C, or whose initial medical evaluation demonstrated the need for a follow-up medical examination: 1) On March 6, 2017, and at prior times, the employer had not provided a follow-up medical examination to an employee whose initial medical evaluation demonstrated the need for a follow-up exam.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.134 F02
- Issued
- Mar 15, 2017
- Abate by
- Apr 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: 1) The employer did not ensure that employees who were required to wear tight-fitting ½ mask respirators were fit tested annually.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 811121)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342149689.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.