Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BOROUGH CONSTRUCTION GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOROUGH CONSTRUCTION GROUP in 952 COLUMBUS AVE, NEW YORK, NY 10025 (NAICS 236116). OSHA activity number 342152527.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Borough Construction Group — free Get an email when a new federal OSHA severe-injury report for Borough Construction Group is published. One employer, no account, unsubscribe in one click.
Site address
952 COLUMBUS AVE
City
NEW YORK
State
NY
ZIP
10025
Mailing
45 W. 34TH ST STE 1001, NEW YORK, NY 10001
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
2
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Other-than-serious 1 instance 1 exposed
Issued
May 17, 2017
Abate by
May 30, 2017
Penalty
Initial $3,802 · Current $2,500 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification.    a) 952 Columbus Ave, Manhattan, NY 10025, On or about 3/1/17: A single gang plug receptacle powering a heater was not installed in accordance with its listing in that it was not permanently affixed to a surface.
Recent events (3)
  • — F (O) $2500
  • — C (S) $3802
  • — Z (S) $3802

1926.403 I02 I

Other-than-serious 1 instance 1 exposed
Issued
May 17, 2017
Abate by
May 30, 2017
Penalty
Initial $6,338 · Current $2,500 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures.      a) 952 Columbus Ave, Manhattan , NY 10025, on or about 3/1/17: Employees were exposed to live parts on an electrical cable that was not properly enclosed at its terminus.
Recent events (3)
  • — F (O) $2500
  • — C (S) $6338
  • — Z (S) $6338

1926.405 B02

Other-than-serious 2 instances 1 exposed
Issued
May 17, 2017
Abate by
May 23, 2017
Penalty
Initial $6,338 · Current $0 Reduced
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers.      a) 952 Columbus Ave, Manhattan, NY, 10025, On or about 3/1/17: Employees were exposed to a power panel cabinet that had a missing cabinet cover which contained live parts.
Recent events (3)
  • — F (O) $0
  • — C (S) $6338
  • — Z (S) $6338

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342152527.