Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GOODWILL INDUSTRIES OF SOUTH FLORIDA, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GOODWILL INDUSTRIES OF SOUTH FLORIDA, INC. in 6201 NW 36TH AVE, MIAMI, FL 33147 (NAICS 813410). OSHA activity number 342153715.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Goodwill Industries of South Florida, INC. — free Get an email when a new federal OSHA severe-injury report for Goodwill Industries of South Florida, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6201 NW 36TH AVE
City
MIAMI
State
FL
ZIP
33147
Mailing
2121 NW 21ST STREET, MIAMI, FL 33142
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
813410
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 6, 2017
Abate by
Oct 2, 2017
Penalty
Initial $9,959 · Current $5,975 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:      On or about 3/07/2017, at the above addressed worksite, procedures for the control of hazardous energy were not documented or utilized by employees who performed maintenance on equipment at the facility.
Recent events (2)
  • — I (S) $5975.4
  • — Z (S) $9959

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 6, 2017
Abate by
Oct 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees:  On or about 3/07/2017, at the above addressed worksite, The employer did not provide training to employees for the control of potentially hazardous energy of a Chicago Skyline S1-S20 commercial laundry folder.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Goodwill Industries of South Florida, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342153715.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.