WASHINGTON, DC —
OSHA Inspection: FRONTIER CONSTRUCTION CO. INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRONTIER CONSTRUCTION CO. INC. in 4980 HILLBROOK LANE, WASHINGTON, DC 20009 (NAICS 238130). OSHA activity number 342161197.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRONTIER CONSTRUCTION CO. INC.
- Site address
- 4980 HILLBROOK LANE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 16505 BARNESVILLE ROAD, BOYDS, MD 20841
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.304 I01
- Issued
- Mar 17, 2017
- Abate by
- Mar 27, 2017
- Penalty
- Initial $3,803 · Current $2,282 Reduced
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed rip saw was not guarded by a hood which completely enclosed that portion of the saw blade above the table and that portion of the saw above the material being cut: a) On or about March 3, 2017; First floor of residential home and on the first floor; employees were using a Ryboi 10 inch table saw that was not equipped with and adjustable guard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2282
- — Z (S) $3803
1926.403 B01 I
- Issued
- Mar 17, 2017
- Abate by
- Mar 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) On or about March 3, 2017; First floor of residential home and on the first floor; the Ryobi table saw used in the process was not equipped with an anti-restart/magnetic switch that would ensure the equipment would not re-start in the event of a power outage and restoration. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 B02
- Issued
- Mar 17, 2017
- Abate by
- Mar 27, 2017
- Penalty
- Initial $1,385 · Current $831 Reduced
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) On or about March 3, 2017; throughout the residential home; the electrical boxes were not protected exposing the employees to the energized conductors. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $831
- — Z (S) $1385
1926.451 G01 VII
- Issued
- Mar 17, 2017
- Abate by
- Mar 27, 2017
- Penalty
- Initial $3,803 · Current $2,282 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about March 3, 2017; Southside exterior of residential home; employees were exposed to a fall 34-foot fall while working on an unguarded scaffold platform. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2282
- — Z (S) $3803
More inspections at Frontier Construction CO. INC.
View Frontier Construction CO. INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342161197.