CHARLESTON, WV —
OSHA Inspection: STRICKLEN REALTY
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of STRICKLEN REALTY in 1552 BRIDGE ROAD, CHARLESTON, WV 25314 (NAICS 236115). OSHA activity number 342162773.
Where did this inspection happen?
- Establishment
- STRICKLEN REALTY
- Site address
- 1552 BRIDGE ROAD
- City
- CHARLESTON
- State
- WV
- ZIP
- 25314
- Mailing
- PO BOX 106, BLUE CREEK, WV 25026
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 7
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.150 C01 I
- Issued
- Abate by
- Penalty
- Initial $1385.00 · Current $762.00 Reduced
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square feet of the protected building area, or major fraction thereof: a.) 1552 Bridge Road, Charleston WV: On or about 03/08/17, a fire extinguisher was not provided for a new construction wood frame residential home that was 3 stories tall.
Recent events (2)
- — I (S) $761.75
- — Z (S) $1385
1926.502 B01
- Issued
- Abate by
- Penalty
- Initial $1847.00 · Current $1016.00 Reduced
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a.) 1552 Bridge Road, Charleston WV: On or about 03/08/17, the guardrail on the second story to protect employees from falling approximately 10' to the first floor, was 36" in height.
Recent events (2)
- — I (S) $1015.85
- — Z (S) $1847
1926.502 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.502(b)(2): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structure members were not installed between the top edge of the guardrail system and the walking/working surface when there was no wall or parapet wall at least 21 inches (53 cm) high. a.) 1552 Bridge Road, Charleston WV: On or about 03/08/17, the guardrail on the second story to protect employees from falling approximately 10' to the first floor had one rail at a height of 36" and no midrail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1051 A
- Issued
- Abate by
- Penalty
- Initial $1847.00 · Current $1016.00 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: a.) 1552 Bridge Road, Charleston WV: On or about 03/08/17, a stairway, ladder, or ramp was not provided for employees gaining access to and from the front porch with a change in elevation of 22". b.) 1552 Bridge Road, Charleston WV: On or about 03/08/17, a stairway, ladder, or ramp was not provided for employees gaining access to and from the garage with a change in elevation of 23".
Recent events (2)
- — I (S) $1015.85
- — Z (S) $1847
1926.1052 C01 I
- Issued
- Abate by
- Penalty
- Initial $1385.00 · Current $762.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a.) 1552 Bridge Road, Charleston WV: On or about 03/08/17, the stairway from the first floor to the second floor consisting of 13 risers did not have at least one handrail.
Recent events (2)
- — I (S) $761.75
- — Z (S) $1385
1926.1052 C12
- Issued
- Abate by
- Penalty
- Initial $1847.00 · Current $1016.00 Reduced
General-duty citation text
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926: a.) 1552 Bridge Road, Charleston, WV: On or about 03/08/17, the second floor stairway landing had a 40.5" long section that was not protected with a guardrail system to prevent employees from falling down the stairs to the first floor.
Recent events (2)
- — I (S) $1015.85
- — Z (S) $1847
1926.404 F06
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a.) 1552 Bridge Road, Charleston WV: On or about 03/08/17, the path to ground for the extension cord supplying power to the Dewalt circular saw was not permanent and continuous in that the ground prong was missing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 236115)
REDDING, CA—2026-07-10
R&A RESOURCES, INC.
FRANCESTOWN, NH—2026-07-10
JM BUILDERS LLC
SAN JOSE, CA—2026-07-09
WALT OXLEY ENTERPRISES, INC.
BATAVIA, OH—2026-07-09
FISCHER SINGLE FAMILY HOMES IV, LLC
SARATOGA SPRINGS, UT—2026-07-09
JESSI CONSTRUCTION & PAINTING LLC
More inspections in WV
NEW MARTINSVILLE, WV—2026-07-08
QUINET'S RESTAURANT
PARKERSBURG, WV—2026-07-07
PEOPLES CARTAGE INC
PROCTOR, WV—2026-07-06
COVESTRO LLC
PARSONS, WV—2026-07-01
A.L.L. CONSTRUCTION, INC.
HUNTINGTON, WV—2026-06-30
CINDY FLORES CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342162773.